期刊文献+

苛性碱、碳酸碱和全碱的同时流动注射分析 被引量:5

Simultaneous Determination of Caustic Soda, Sodium Carbonate and Total Soda in Sodium Aluminate Solutions by Flow Injection Titration
下载PDF
导出
摘要 采用流动注射滴定技术实现了氧化铝生产过程中铝酸钠溶液中苛性碱、碳酸碱和全碱的同时自动分析。以磺基水杨酸为载流,它既为滴定剂又是铝的掩蔽剂;酚酞和甲基橙混合液为试剂流,它们是苛性碱、碳酸碱和全碱的指示剂。该法可测定6.2~30.9g/L的碳酸碱和3.1~15.5g/L的苛性碱(均以Na2O计),测定速率30个样/h,相对标准偏差优于0.5%(n=11,Na2O=21.94g/L)。 Simultaneous determination of caustic soda, carbonate,and total soda in sodium aluminate solutions is realized by flow injection titration with a mixture of methyl orange and phenolphthalein as the corresponding indicators for the determination of caustic soda, sodium carbonate and total soda. Sulfosalicylic acid, the carrier, is both the titrant and complexing agent for aluminum.The method can be used for the the analysis of the sample containing caustic soda, sodium carbonate and total soda in the range of 6. 2 ~ 30. 9 g/L and 3. 1 ~ 15- 5 g/L (expressed as Na2O) with a sampling freqUency of 30 Samples per hour. A relative standard deviation of 0. 5% is obtalned for 11determinations of a typical sample containing 21. 94 g/L of sodium oxide.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 2000年第3期303-306,共4页 Chinese Journal of Analytical Chemistry
关键词 流动注射 苛性碱 碳酸碱 铝酸碱 全碱 氧化铝 Flow injection titration, caustic soda, sodium carbonate, aluminate, total soda
  • 相关文献

参考文献1

二级参考文献3

  • 1谭爱民,1993年
  • 2黄家林,Talanta,1992年,39卷,6期,589页
  • 3徐淑坤,流动注射分析,1991年

共引文献8

同被引文献120

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部