期刊文献+

基于姿态矩阵判据的光学焦距在线快速标定

Online fast calibration of optical focal length based on attitude matrix criterion
下载PDF
导出
摘要 针对在轨运行的微小航天器发射过程的振动引起的结构变形和在轨太阳光照产生的结构热变形会使发射前对惯性恒星罗盘(Inertial Stellar Compass:ISC)标定的光学系统焦距偏离实际值,进而影响微小航天器的高精度姿态确定的问题,提出了一种基于姿态矩阵判据的ISC光学系统焦距在线快速标定方法。首先,分析了光学系统焦距与姿态矩阵的映射关系;然后,利用任一时刻由滤波生成的姿态矩阵,结合姿态矩阵单位正交特性的这一判据,采用迭代法实现了ISC光学系统焦距的在线快速标定。实验结果表明:该方法对ISC光学系统焦距的标定精度同星点质心提取的像素精度相当,大约为0.01个像素。该方法可在轨随时进行光学系统焦距的标定,标定速度快,且不需要采集大量姿态测量传感器的数据,标定效果良好。 The structure deformation of a micro-spacecraft in orbit caused by launching vibration and its thermal deformation resulted from sunlight will change the optical focal length of an Inertial Stellar Compass(ISC) in the calibration before launching.Furthermore,it will affect on the high-precision attitude determination for the micro-spacecraft.To improve the calibration,an online fast calibration method based on the attitude matrix criterion was presented.Firstly,this method was used to analyze the mapping relation between the optical focal length and the attitude matrix.Then,combining the attitude matrix generated by the filter in any time with the orthogonal unit features of attitude matrix,the focal length of ISC was calibrated online based on an iterative method.Experimental results indicate that the calibration precision by proposed method for the optical length of the ISC system is equivalent to the extracting precision by the stellar center of mass method,and it is about 0.01 pixel.This method can calibrate the focal length at any time in orbit,and have fast calibration speeds and better calibration results without capturing a large number of other attitude measurement data from sensors.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2012年第5期934-941,共8页 Optics and Precision Engineering
基金 国家自然科学基金资助项目(No.61004140,No.60825305,No.61104198)
关键词 惯性恒星罗盘 标定 光学焦距 姿态矩阵 Inertial Stellar Compass(ISC) calibration optical focal length attitude matrix
  • 相关文献

参考文献14

二级参考文献30

  • 1陈刚,车仁生,叶东,黄庆成.一种基于立体模板的双目视觉传感器现场标定方法[J].光学精密工程,2004,12(6):626-631. 被引量:28
  • 2魏霖,王从军.多关节坐标测量机的坐标转换和参数标定[J].光电工程,2007,34(5):57-61. 被引量:15
  • 3JORGE S. A crenellated-target-based calibration meth od for laser triangulation sensors integration in articula ted measurement arms[J]. Robotics and Computer-In- tegrated Manufacturing, 2011,27(2) : 282-91.
  • 4JORGE S, JUAN-JOS A, JOS A Y, et al.. Kine- matic parameter estimation technique for calibration and repeatability improvement of articulated arm co- ordinate measuring machines [J]. Precision Engi- neering, 2008,32(4) : 251-68.
  • 5MAHMOUD T,MIKYUNG K. Inverse kinematics of 7-DOF robots and limbs by decomposition and approximation [J]. IEEE Transactions on Robotics 2007,23(3): 595-600.
  • 6WANG X Y, LIU SH G, ZHANG G X. Calibra- tion technology of the articulated arm flexible CMM [J]. Key Engineering Materials, 2008,381/382 161-164.
  • 7LIGHTCAP C, HAMNER S, SCHMITZ T, et al.. Improved positioning accuracy of the PA10- 6CE robot with geometric and flexibility calibration [J]. IEEE Transactions on Robotics, 2008,24 (2) : 452-456.
  • 8BURNER A, LIU T.Videogrammetric model deformation measurement technique[J].Journal of Aircraft, 2001, 38(4):745-754.
  • 9CHANG C, JI Y.Flexible videogrammetric technique for three-dimensional structural vibration measurement[J].Journal of Engineering Mechanics, 2007,133(6):656-664.
  • 10WOODHOUSE N, ROBSON S, EYRE J.Vision metrology and three dimensional visualization in structural testing and monitoring[J].The Photogrammetric Record, 1999, 16(94):625-641.