以2009年成都"6.5"公交车放火案件为例,根据火灾现场勘查、证人证言和公交车全尺寸火灾实验,分析公共汽车防火设计存在的缺陷,总结事故的教训,对公共汽车防火本质安全提出针对性的对策。
Taking chengdu"6·5"bus burning as an example,according to fire renaissance,testimony of witnesses and full-scale fire experiment,defects of bus fire protection design was analyzed,experience was concluded,and the countermeasures for essential safety of bus fire protection design were proposed.