期刊文献+

弱电网条件下单相光伏并网逆变器的控制研究 被引量:6

Study of Controlling a Single-phase Photovoltaic Grid-connected Inverter Operating in a Weak Grid
下载PDF
导出
摘要 单相全桥逆变器单极性正弦脉宽调制(SPWM)相对于双极性调制损耗低,电磁干扰少,更适用于逆变控制,但该调制方式存在一个过零点振荡。在弱电网条件下,由于电网波形畸变,对电网电压的过零点处理尤为关键。针对过零点问题,在并网条件下,采用基于二阶广义积分器(SOGI)的单相锁相环检测电网电压过零点,与传统的过零鉴相相比,具有良好的效果,并在一台4 kW的单相光伏并网逆变器上得到了验证。 The monopole SPWM inverter has merits of lower loss, lower EMI comparing with bipolar SPWM inverter. It's fit the needs of SPWM control than others methods.But the monopole SPWM still has its disadvantage,the zero point oscillation.In a weak grid, due to the grid aberrance, it's key of dealing with the zero point.This paper aiming at the zero point,operating in a connected grid, adopting a single phase-locked-loop based on second order general- ized integrator(SOGI) test the zero point is introduced, comparing with conventional capture, it has a well effect.The mothed is demonstrated with experiment in a 4 kW single-phase photovoltaic grid-connected inverter.
机构地区 合肥工业大学
出处 《电力电子技术》 CSCD 北大核心 2012年第5期36-38,共3页 Power Electronics
关键词 逆变器 单极性 过零点振荡 弱电网 inverter monopole zero point oscillation weak grid
  • 相关文献

参考文献4

  • 1李晟婷,戴训江.弱电网对光伏并网逆变器电流滞环控制的影响分析[J].低压电器,2010(20):8-13. 被引量:3
  • 2S M Silva, L N Arruda, B J C Filho, et al.Performance Eva- luation of PLL Algorithms for Single-phase Grid-connected Systems[A].Industry Applications Conference, 39th IAS Annual Meeting[C].2004 : 2259-2263.
  • 3P Rodriguez, A Luna, I Candela, et al.Grid Synchroniza- tion of Power Converters using Multiple Second Order Generalized Integrators[A].Industrial Electronics,34th An- num Conference of IEEE[C].2008:755-760.
  • 4Ciobotaru M, Teodorescu R, Blaabjerg F.A New Single- phase PLL Structure Based on Second Order Generalized Integrator[A].Power Electronics Specialists Conference,37th IEEE[C].2006 : 1-6.

二级参考文献13

  • 1CAVALCANTI M C, AZEVEDO G M S. A photovoltalc generation system with unified power quality conditioner function [ C ] //Industrial Electronics Society IECON 2005, 31 st Annual Conference of IEEE 2005 : 6-12.
  • 2GUIMARAES G C, SANHUEZA S M R. Optimization of a photovoltaic system connected to electric power grid [ C ]//Transmission and Distribution Conference and Exposition, IEEE/PES: 2004 645-650.
  • 3TUMBELAKA H H, BORLE L J. A grid current-controlling shunt active power filter [ C ]//Power Electronics, 2007. ICPE '07. 7th Internatonal Conference, 2007:956-961.
  • 4TEODORESCU R, BLAABJERG F. A new control structure for grid-connected LCL pv inverters with ze- ro steady-state error and selective harmonic compen- sation [ C ]//IEEE Applied Power Electronics Conference and Exposition, 2004 : 1-6.
  • 5BUCHHOLZ B M, STYCZYNSKI Z A. Dynamic simulation of renewable energy sources and requirements on fault ride through behavior [ C ]//Power Engineering Society General Meeting, IEEE, 2006 : 1-7.
  • 6SERPA L A, KOLAR J W, PONNALURI S. A modi- fied direct power control strategy allowing the connection of three-phase inverter to the grid through lcl fil- ters[ C ]//Conference Record of the Fourth IAS Annual Meeting, 2005 : 1-8.
  • 7ENSLIN J, HESKES P. Harmonic interaction between a large number of distributed power inverters and the distribution network [ J ]. IEEE Transactions on Power Electronics, 2004,19 ( 6 ) : 1586-1593.
  • 8LISERRE M, TEODORESCU R. Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values [ J ]. IEEE Transactions on Power Electronics, 2006,21 ( 1 ) :263-272.
  • 9BUSO S, FASOLO S, MALESAN L. A dead-beat adaptive hysteresis current control[ J]. IEEE Transactions on Industry Applications, 2000,36 ( 1 ) : 1174- 1180.
  • 10CHRISTIAN P DICK, SEBASTIAN RICHTER. Active damping of LCL resonance with minimum sensor effort by means of a digital infinite impulse response filter [ J ]. IEEE Transaction on power electronics, 2007 : 1-8.

共引文献2

同被引文献63

  • 1王正仕,陈辉明.具有无功和谐波补偿功能的并网逆变器设计[J].电力系统自动化,2007,31(13):67-71. 被引量:32
  • 2袁小明.长线路弱电网情况下大型风电场的联网技术(英文)[J].电工技术学报,2007,22(7):29-36. 被引量:22
  • 3LISERRE M, TEODORESCU R, BLAABJERG F. Stability of photovoltaic and wind turbine grid - connected inverters for a large set of grid impedance values [ J]. IEEE Transactions on Power E- lectronics, 2006, 21 ( 1 ) :263 -272.
  • 4TWINING E, HOLMES D G. Grid current regulation of a three - phase voltage source inverter with an input LCL fiher [ J ]. IEEE Transactions on Power Electronics, 2003, 18 (3) :888 -895.
  • 5MALINOWSKI M, BERNET S. A simple voltage sensorless active damping scheme for three - phase PWM converters with an LCL filter [ J]. IEEE Transactions on Industrial Electronics, 2008, 55 (4) : 1876 -1880.
  • 6SHEN Guoqiao, XU Dehong, CAO Luping, et al. An improved control strategy for grid - connected voltage source inverters with an LCL filter [ J ]. IEEE Transactions on Power Electronics, 2008, 23(4) : 1899 - 1906.
  • 7GABE I J, MONTAGNER V F, PINHEIRO H. Design and imple- mentation of a robust current controller for VSI connected to the grid through an LCL filter [ J ]. IEEE Transactions on Power Elec- tronics, 2009, 24(6) :1444 - 1452.
  • 8YANG Shuitao, LEI Qin, PENG F Z, et al. A robust control scheme for grid - connected voltage - source inverters [ J ]. IEEE Transactions on Industrial Electronics, 2011,58( 1 ) :202 -212.
  • 9Kothari D P,Singal K C,Ranjan R.Renewable energy sources and emerging technologies[M].Second Edition.New Delhi:PHI Learning Private Limited,2012:196-197.
  • 10Cobreces S,Bueno E,Rodriguez F,et al.Influence analysis of the effects of an inductive-resistive weak grid over L and LCL filter current hysteresis controllers[C]// European Conference on Power Electronics and Applications.Aalborg:Inst. of Elec. and Elec. Eng. Computer Society,2007:1-10.

引证文献6

二级引证文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部