通过对神东电力公司热电分公司DG520/13.7-域1型循环流化床锅炉,在运行过程中出现的屏式过热器局部管束壁温超温、主蒸汽和再热蒸汽汽温偏低的问题进行了原因分析,并提出了有效的运行调整措施。
In this paper, the thermal power plant DG520 god / 13.7- Ⅱ type 1 circulating fluidized bed boiler operation in appeared in the process of screen type superheater bundle wall temperature, and local WenChao main steam and hot steam again low steam temperature of reason analysis, and put forward effective operation adjustment measures.
出处
《神华科技》
2012年第3期71-73,共3页
Shenhua Science and Technology
关键词
循环流化床锅炉
超温
分析
治理
Circulating fluidized bed boiler
Over-temperature
Analysis
Treatment