摘要 针对某公司CFB锅炉掺烧后出现的水冷壁磨损问题,分析了引发磨损的多种原因,采取了针对性防磨措施,取得了良好的效果,提高了锅炉运行的安全性和稳定性,对同类型的CFB锅炉预防水冷壁磨损具有一定的参考价值。 The paper discussed abrasion problems of water wall after a mixed burning in certain corporation's CFB boiler. A variety of abrasion reasons have been analyzed and special anti-abrasion measurements have been taken to improve the boiler's safety and stability under operation. It can be found that good results have been achieved and will provideimportant reference value for the same type of CFB boiler water wall to prevent abrasion.
作者 王富兴 忻炜
出处 《电力科学与工程》 2012年第4期74-78,共5页 Electric Power Science and Engineering
关键词 CFB锅炉 水冷壁 磨损 CFB boiler bater ball abrasion