期刊文献+

炉烟法除垢影响因素的试验研究 被引量:4

Investigation of Influencing-factor by Using the Mixture of Water and Flue Gas to Remove Scale
下载PDF
导出
摘要 :通过利用CO2 对人工垢样及实际垢样的溶解实验 ,得出了灰垢中CaCO3 含量及气水混合体中溶解CO2浓度是影响灰垢溶解速度的 2个关键因素 ,在此基础上 ,得出了灰垢的总去除量与溶解量的关系 ,为炉烟法除垢的实际应用提供了依据 . The two important factors of influencing scale concentration are content of CaCO 3 in the scale and CO 2 concentration in the mixture by water and gas. Those were summarized by dissolve experiment of manual and practical scale by using CO 2. At that base,the connection between the total capacity of removing scale and the solvency was summarized. These offered the thereunder for the practical application of the mixture by water and flue gas to remove scale.
出处 《长沙水电师院学报(自然科学版)》 2000年第1期87-89,共3页
关键词 火电厂 水力除灰系统 炉烟法 除垢 power plant the system of water removal scale the mixture of water and flue gas remove scale
  • 相关文献

参考文献4

二级参考文献26

共引文献16

同被引文献13

  • 1徐鸣,徐奇焕.燃煤电厂炉烟循环水处理的实践[J].四川电力技术,1993,16(4):34-39. 被引量:2
  • 2于英利,沈炳耘,吴凤英,王丽峰.火电厂炉烟处理循环冷却水防垢试验研究[J].工业水处理,2006,26(6):36-38. 被引量:3
  • 3Moccari,Ahmad A. Corrosion Inhibitor Evaluation for Materials Used in Closed Cooling Water Systems [J].Materials Performance, 1996.23(6): 16~18.
  • 4W.A. Mitchell,G. A. Small, M. A. Reinsalu. The Use of Novel Monitoring and Control Technology in Cooling Water System to Lower Operating Costs [J]. National Association of Corrosion Engineers. 2000. 4:263~265.
  • 5中华人民共和国水力电力部.火力发电厂水、汽试验方法[M].北京:水利电力出版社,1984.29-81.
  • 6中华人民共和国化工行业标准.冷却水动态模拟试验方法[M].北京:中国计划出版社,1993:4—22.
  • 7Jim-kuk kim,Guang lee,Frank zhu,et al.Cooling system design[J].Heat Transfer Engineering,2002,2(6):49-61.
  • 8中华人民共和国水力电力部.火力发电厂水、汽试验方法[S].北京:水利电力出版社,1984:29-81.
  • 9中华人民共和国化工行业标准.冷却水动态模拟试验方法[S].北京:中国计划出版社,1993:4-22.
  • 10W.A.Mitchell,G.A.Small,M.A.Reinsalu.The Use of Novel Monitoring and Control Technology in Cooling Water System to Lower Operating Costs.National Association of Corrosion Engineers.2000.4.