摘要 本文针对设置早期抑制快速响应喷头自动喷水灭火系统的高架仓库的自动喷水灭火系统配水管网,分别以不同的流速控制条件进行计算,得出配水管网重量、系统流量、供水压力等参数,据此分析其对高架仓库结构带来的影响,综合比较不同的计算流速最终对高架仓库工程造价的影响,由此对高架仓库自动喷水灭火系统管网计算流速的选择提出建议。 This paper suppression sprinkler distribution networks, focuses on the pipe network of high rack storage which setting fast response early system, calculate flow velocity control in different conditions, draw weight of water system parameters such as flow, water pressure, Analysis on the impact of the high rack storage structure, comparing different of high rack storage, and pointed out that high velocity selection recommendations. final calculation of flow velocity effect on construction cost rack storage sprinkler system piping network calculation of
出处 《粮食流通技术》 2012年第2期14-16,23,共4页 Grain Distribution Technology
关键词 高架仓库 快速响应早期抑制喷头 管网重量 工程造价 High rack storage Fast response early suppression sprinklers Weight of pipe network Project cost