期刊文献+

基于准三维模型的垂直U型埋管换热特性影响因素的分析 被引量:4

Analysis on Influence Factors of Heat Exchange Characteristics of Vertical U-bend Ground Heat Exchanger Based on Quasi-three Dimensional Model
下载PDF
导出
摘要 为了探讨各因素对地源热泵地下埋管换热特性的影响,建立了同时考虑流体温度沿程变化与U型两支管热干扰的垂直U型埋管准三维传热解析解模型。基于模型求解,分析了回填物与管材导热性、管脚间距、循环流体流量及钻孔深度等对埋管换热特性的影响。结果表明:回填物与管材的导热性、管脚间距及循环流体流量的加大均可以强化地下换热器的换热效果。但回填物导热性不可无限制增大,其大小要考虑对增大管脚热干扰的影响及其与管脚间距的相互关联性,应对两者进行优化设计。同时,流体流量的加大会增加单位埋管换热量,但其增加幅度越来越小,应以流动阻力增加作为限制条件,采用变流量调节来进行优化。此外,单个钻孔不宜太深,以免降低单位埋管换热能力。试验验证表明,所建模型具有一定的预测精度,其最大预测相对误差在3%以内,可为地埋管换热器传热特性分析及其优化设计提供参考。 In order to investigate the influences of various factors on heat exchange characteristics of ground heat exchangers(GHE),a quasi-three dimensional heat transfer analytical model was developed for the vertical U-bend GHE.The variation of fluid temperature along the U-tube and the thermal interference between two adjacent legs of U-tube were considered in this model.Based on the solution of the model,the influences of various factors,which include the thermal conductivity of grout and pipe,spacing between the two legs of U-tube,flow rate of circulated fluid and borehole depth,on the heat exchange characteristics of GHE were discussed.The results indictate that the increase in the thermal conductivity of grout and pipe,spacing between the two legs and fluid flow rate can all improve heat exchange effectiveness of GHE.But the thermal conductivity of grout should not be increased unrestrictedly,the decision of its value has to take into account the influence of increased thermal interference between the two-legs and its correlation with the spacing of two legs,and should be further optimized for them.At the same time,the increase of fluid flow rate can lead to the increase of heat flow per unit buried coil length,but the increasing degree become more and more small,a restriction in flow resistance increase must be taken into account to optimize it by a variable flow rate design method.Addionally,the depth of a borehole should not be too large in case that the heat exchange rate per unit coil length should decrease.The experimental validation shows that the predicted relative error is less than 3%.This means that the model developed can provide references for the analysis of heat exchange characteristic and optimization design of GHE.
机构地区 扬州大学 东南大学
出处 《流体机械》 CSCD 北大核心 2012年第4期56-62,共7页 Fluid Machinery
基金 国家"十一五"科技支撑计划项目资助(2008BAJ12B04) 中国博士后科学基金项目资助(20090461050) 住房与城乡建设部科技计划项目资助(2008-K1-26) 扬州大学"新世纪人才工程"优秀青年骨干教师计划项目(2008年度) 扬州大学科技创新培育基金项目(2010CXJ030) 江苏省科技支撑计划项目(BE2010699)
关键词 地源热泵 垂直U型埋管换热特性 准三维模型 影响因素 试验验证 ground source heat pump heat exchange characteristics of vertical U-bend ground heat exchanger quasi-three dimensional model influence factors experimental validation
  • 相关文献

参考文献10

  • 1Kavanaugh S P. Simulation and Experimental Verica- tion of Vertical Ground-coupled Heat Pump Systems [D]. Stillwater: Oklahoma State University, 1986.
  • 2Deerman J D, Kavanaugh S P. Simulation of Vertical U-tube Ground-coupled Heat Pump Systems Using the Cylindrical Heat Source Solution[ J ]. ASHRAE Trans- actions, 1991,97( 1 ) :287294.
  • 3Gu Y, O' Neal D L. Development of an equivalent di- ameter expression for vertical U-tubes used in ground- coupled heat Pumps [ J ]. ASHRAE Transactions, 1998,104(2) :347-355.
  • 4Gu Y, O' Neal D L. Modeling the Effect of Backfills on U-tube Ground Coil Performance [ J ]. ASHRAETransactions, 1998, 104(2):356-365.
  • 5Diao N R, Cui P, Fang Z H. The Thermal Resistance in A Borehole of Geothermal Heat Exchange [ C ]. Proc. 12th International Heat Transfer Conference. France, 2002: 239-343.
  • 6Kavanangh S P, K Rafferty. Ground-source Heat pumps : Design of Geothermal Systems for Commercial and Institutional Buildings [ M ]. Atlanta: ASHRAE, Inc. 1997.
  • 7Hellstrom G. Ground heat storage [ D ]. Doctoral The- sis, Sweden: Department of Mathematical Physics, U- niversity of Lund, 1991.
  • 8杨卫波,朱洁莲,谢治祥.地源热泵地下岩土热物性现场热响应测试方法研究[J].流体机械,2011,39(9):57-61. 被引量:13
  • 9杨卫波,倪美琴,施明恒,吴安宽,冯学.太阳能-地源热泵系统运行特性的试验研究[J].流体机械,2009,37(12):52-57. 被引量:19
  • 10刘建,张正国,高学农,王真勇.螺旋折流板与弓型折流板强化管换热器的传热性能对比[J].压力容器,2011,28(3):12-15. 被引量:16

二级参考文献32

共引文献45

同被引文献56

  • 1魏紫娟,秦萍.土壤源热泵地下垂直埋管换热器常用传热模型的研究[J].制冷与空调(四川),2004,18(3):17-21. 被引量:14
  • 2杨卫波,施明恒.基于线热源理论的垂直U型埋管换热器传热模型的研究[J].太阳能学报,2007,28(5):482-488. 被引量:50
  • 3Commercial/institutional ground-source heat pump en- gineering manual [ M ]. Atlanta: American Society of Heating Refrigerating and Air-conditioning Engineer- ings, Inc, 1995.
  • 4Gilbreath C S. Hybrid ground source heat pump system for commercial application[ D]. Master's thesis. Uni- versity of Alabama. Tuscaloosa. 1996.
  • 5Kavanaugh S P. A design method for hybrid ground- source heat pumps [ J ]. ASHRAE Transactions, 1998, 104(2) :691-698.
  • 6Phetteplace G, Sullivan W. Performance of a hybrid GCHP system[ J] . ASHRAE Transactions, 1998,104 ( 1 ) :763-770.
  • 7Singh J B, Foster G. Advantages of using the hybrid ge- othermal options [ M ]. The second Stockton College of New Jersey, 1998.
  • 8Chiasson A D,Spitler J D, Rees S J. A model for sim- dating the performance of a pavement heating system as a supplemental heat rejecter with closed loop ground source heat pump systems [ J ]. ASME Journal of Solar Energy Engineering,2000,122( 11 ) : 183-191.
  • 9Chiasson A D, Spitler J D, Rees S J. A model for sim-ulating the performance of a shallow pond as a supple- mental heat rejecter with closed loop ground source heat pump systems [ J ]. ASHRAE Transactions, 2000, 106(2) :107-121.
  • 10Yavuzturk C and Spitler J D. Comparative study of operating and control strategies for hybrid ground source heat pump systems using a short time step simulation model[ J ] . ASHRAE Transactions,2000, 106(2) : 192-209.

引证文献4