摘要
以某火车站为例,分析了地源热泵系统的施工特点,从质量预控、施工机械设备、回灌质量要求、半成品保护等方面对地源热泵系统提出了具体的施工管理措施,以降低地源热泵系统的故障率,使系统发挥更大的作用。
Take a example of a railway station to analyze ground source heat pump system construction features,from the quality of pre-control,construction machinery and equipment,recharge the quality requirements,protection of semi-finished products in terms of ground source heat pump system made specific construction management measures,so as to reduce failure rate of ground source heat pump system and to play its far more important role.
出处
《山西建筑》
2012年第1期142-143,共2页
Shanxi Architecture
关键词
地源热泵系统
垂直度
回灌比例
导热效果
ground source heat pump system
verticality
recharge ratio
thermal effects