期刊文献+

大功率三相光伏并网逆变器散热系统设计

Heat Dissipation Design of Three Phase PV Grid-connected Inverters
下载PDF
导出
摘要 针对大功率三相光伏并网逆变器散热设计难题,研究了一种准确且实用的IGBT模块损耗计算方法,并给出了散热器热阻的实用计算公式.在此基础上设计了一套采用强迫风冷的散热系统,实验证明模块外壳温度的计算结果与实际结果相差只有5℃,说明了该设计方法的合理及实用性. A practical method to design the heat dissipation system of the three phase photovoltaic Grid-connected inverter was presented.the switching losses of the IGBT module used in the inverter were calculated.A practical formula to calculate the heat resistance of heat dissipation system was given.A heat dissipation system for the inverter using forced-air-cool was designed.The calculated results and the experiment results verify the validity and practicability of the presented design method.
出处 《哈尔滨理工大学学报》 CAS 2012年第2期27-30,共4页 Journal of Harbin University of Science and Technology
基金 国家科技重大专项(2009ZX02011-02) 住房和城乡建设部科技项目(建科2008 100号)
关键词 三相光伏并网逆变器 热阻 散热系统 three phase photovoltaic grid-connected inverter heat resistance heat dissipation system