期刊文献+

根管偏移的研究进展 被引量:1

下载PDF
导出
摘要 根管预备是根管治疗的关键步骤,其主要目的是清洁和成形,清除根管内坏死物、微生物及代谢产物,去除根管壁感染的牙本质,成形根管以利于充填.但由于复杂的根管解剖形态和不同根管扩大器械及方法,都将引起根管形态的变化,其中最常见的并发症之一是根管偏移.根管偏移是根管预备器械偏离根管中轴,过度切削管壁,预备后的根管未维持原根管走向的现象.
出处 《西南国防医药》 CAS 2012年第5期566-567,共2页 Medical Journal of National Defending Forces in Southwest China
  • 相关文献

参考文献15

  • 1范兵,樊明文,边专,吴民凯,P.R.Wesselink.根管偏移对充填材料封闭根管能力的影响[J].口腔医学纵横,2001,17(2):83-87. 被引量:62
  • 2Peters O A.Current challenges and concepts in the preparation of root canal systems:a review[J].J Endodon,2004,30(8):559-566.
  • 3钟素兰,尹仕海,陈朝辉,揭有琼,汪莉.Micro-CT评价不同弯曲度根管预备后根尖偏移的实验研究[J].国际口腔医学杂志,2009,36(6):657-660. 被引量:8
  • 4Schfer E,Erler M,Dammaschke T.Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instrument.Part 1 Shaping ability in simulated curved canals[J].Int Endod J,2006,39:196-202.
  • 5Schfer E,Erler M,Dammaschke T.Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments.Part 2 Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth[J].Int Endod J,2006,39:203-212.
  • 6Iqbal M K,Maggiore F,Suh B,et al.Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques[J].J Endod,2003,29(9):587-591.
  • 7Iqbal M K,Firic S,Tulcan J,et al.Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments[J].Int Endod J,2004,37(6):359-364.
  • 8Loizides A L,Kakavetsos V D,Tzanetakis G N,et al.A comparative study of the effects of two nickel-titanium preparation techniques on root canal geometry assessed by microcomputed tomography[J].J Endod,2007,33(12):1455-1459.
  • 9凌均棨,刘沛,韦曦.ProFile器械两种预备方法对弯曲根管成形作用的实验研究[J].中华口腔医学杂志,2003,38(4):278-278. 被引量:2
  • 10Wu M K,Wesselink P R.Efficacy of three techniques in cleaning the apical portion of curved root canals[J].Oral Surg Oral Med Oral Pathol,1995,79:492-496.

二级参考文献42

  • 1Kosa DA, Marshall G, Baumgartner JC. An analysis of canal centering using mechanical instrumentation techniques[J]. J Endod, 1999, 25(6):441-445.
  • 2Versumer J, Htllsmann M, Schafers F. A comparative study of root canal preparation using Profile .04 and Lightspeed rotary Ni-Ti instruments[J].Int Endod J, 2002, 35 (1) : 37-46.
  • 3Ozgur Uyanik M, Cehreli ZC, Ozgen Mocan B, et al.Comparative evaluation of three nickel-titanium instrumentation systems in human teeth using computed tomography [J]. J Endod, 2006, 32(7):668-671.
  • 4Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part Ⅰ: Effects of apical transportation on seal of root fillings[J]. J Ended, 2000, 26(4) :210-216.
  • 5Stamm T, Kaup M, Hohoff A, et al. Validity of a three-dimensional public-domain system for contemporary endodontic research[J]. J Endod, 2003, 29(12):801-805.
  • 6Schneider SW. A comparison of canal preparations in straight and curved mot canals[J]. Oral Surg Oral Med Oral Pathol, 1971, 32(2):271-275.
  • 7Hartmann MS, Barletta FB, Camargo Fontanella VR, et al. Canal transportation after root canal A comparative study with computed tomography[J] Endod, 2007, 33 (8):962-965.
  • 8Southard DW, Oswald R J, Natkin E. Instrumentation of curved molar root canals with the Roane technique[J]. J Endod, 1987, 13 (10) : 479-489.
  • 9Bramante CM, Berbert A, Borges RP. A methodology for evaluation of root canal instrumentation[J]. J Endod, 1987, 13 (5) : 243-245.
  • 10Peters OA, Laib A, Gohring TN, et al. Changes in root canal geometry after preparation assessed by high-resolution computed tomography[J]. J Endod, 2001, 27 (1): 1-6.

共引文献70

同被引文献31

  • 1Schafer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K - Flexofile part I shaping ability in simulated curved canals [ J 1. Int Endod, 2002, 35(6) : 505 -513.
  • 2Vandt J, Bitter K, Neumann K, et al. Ex vivo study on root ca- nal instrumentation of two rotary nickel-titanium systems in com- parison to stainless steel hand instruments [ J ]. Int Endod J, 2009,42( 1 ) :22 -33.
  • 3Shen Y, Qian W, Abtin H, et al. Fatigue testing of controlled memory wire nickel-titanium rotary instruments [ J]. J Ended, 2011,37(7) :997 - 1001.
  • 4Yared G. Canal preparation using only one Ni-Ti rotary instru-ment: preliminary observations I J]. lnt Endod J, 2008, 41 (4) : 339 -344.
  • 5Yared G. Canal preparation with only one reciprocating instru- ment without prior hand filing: a new concept [ J]. Aust Dent Prac, 2011,22: 178.
  • 6Htilsmann M, Peters OA, Dummer PMH. Mechanical prepara- tion of root canals : shaping goals, techniques and means [ J ]. Endod Topics, 2005, 10:30 - 76.
  • 7Gambarini G, Grande NM, Plotino G, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [ J ]. J Endod, 2008, 34 ( 8 ) : 1003 - 1005.
  • 8Larsen M, Watanabe I, Gliekman GN, et al. Cyclic fatigue a- nalysis of a new generation of nickel titanium rotary instruments [J]. J Endod, 2009,35(3) :401 -403.
  • 9Gambarini G, Gerosa R, De Luea M, et al. Mechanical proper- ties of a new and improved nickel - titanium alloy for endodontie use: an evaluation of file flexibility [J]. Oral Surg Oral Med O- ral Pathol Oral Radiol Endod, 2008,105 (6) :798 - 800.
  • 10Ahmed AR H, Angie GG, Reem AL, et al. Geometric analysis of root canals prepared by four rotary NiTi shaping systems [ J]. JEndod, 2012, 38(7): 996-1000.

引证文献1

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部