期刊文献+

液晶空间光调制器在生物光学显微中的应用

The Applicaton of LCSLM in Biological Optical Microscopy
下载PDF
导出
摘要 利用液晶空间光调制器(LCSLM)对光学显微中的成像光进行实时的相位/振幅调制,不仅可以实现各种传统的生物样品相位显微,而且能够以更复杂的相位调制方式,如螺旋相位滤波,得到新的显微图像。该方式已经和荧光显微、光镊技术结合,丰富了生物显微技术。 With the light modulation of the liquid crystal spatial light modulators (LCSLM) in the imaging path in microscopy, one can not only simulate traditional methods of contrast phase microscopy, but also realize the new technology in the microscopy of biological samples through the more complex phase modulation. The combination of LCSLM with optical tweezers or fluorescence, improves the biological optical microscopy a lot.
出处 《激光生物学报》 CAS CSCD 2012年第2期97-102,117,共7页 Acta Laser Biology Sinica
基金 国家863计划(2007AA021811 2007AA021809) 中国科学院知识创新工程(KJCX2-YW-H-10)
关键词 显微 液晶空间光调制器 相位衬比 螺旋相位衬比 microscopy LCSLM contrast phase spiral phase contrast
  • 相关文献

参考文献18

  • 1KIM M K. Digital holographic microscopy: principles, techniques,and applications, springer series in optical sciences 162 [M]. Berlin, Heidelberg:Springer, 2011, 149-190.
  • 2FURHAPTER S, JESACHER A, BERNET S, et al. Spiral phase contrast imaging in microscopy[ J]. Opt Express, 2005,13(3) :689-694.
  • 3WARBER M, ZWICKS, HASLER M, et al. SLM-based phase-contrast filtering for single and multiple image acquisition [ J]. Proc SPIE, 2009, 7442:74420E.
  • 4MAURER C, JESACHER A, BERNET S, et al. What spatial light modulators can do for optical microscopy [ J ]. Laser & Photon Rev, 2011,5(1) :81-101.
  • 5MCINTYRE T J, MAURER C, BERNET S, et al. Differential interference contrast imaging using a spatial light modulator [J]. Opt Lett, 2009, 34(19) :2988-2990.
  • 6MCINTYRE T J, MAURER C, FASSL S, et al. Quantitative SLM-based differential interference contrast imaging [ J ]. Opt Express, 2010,18 ( 13 ) : 14063-14078.
  • 7MAURER C, JESACHER A, FURHAPTER S, et al. Upgrading a microscope with a spiral phase plate [ J ]. J Microsc, 2008, 230 : 134-142.
  • 8MAURER C, BERNET S, RITSCH-MARTER M. Refining common path interferometry with a spiral phase fourier filter [J]. J Opt A Pure Appl Opt, 2009, 11:094023.
  • 9WEI Shibiao, BU Jing, ZHU Siwei, et al. Image edge-enhancement in optical microscopy with a phase mismatched spiral phase plate [ J ]. Chin Opt Lett, 2011, 9 ( 3 ) : 031001.
  • 10SHAMA M K, JOSEPH J, SENTHIKUMARAN P. Selective edge enhancement using anisotropic vortex filter[ J]. Appl Opt, 2011, 50(27) :5279-5286.

相关作者