摘要 针对高压脉冲电场杀菌技术对于系统核心部分高压脉冲电源的要求,设计一种输出脉冲电压峰值可达5~30 kV(100 V步进可调),输出脉冲频率为200~1 000 Hz可调,脉冲宽度为0.2~2μs可调,脉冲前沿〈100 ns的高压脉冲电源。该系统利用单片机进行自动控制,通过可调直流高压电源和储能元件作为能源系统,利用氢闸流管作为主放电开关,控制脉冲峰值和频率,最后通过脉冲变压器升压在杀菌腔体的极板上得到所需的脉冲电场。 With the aim to meet the requirements of high-voltage pulsed electric field sterilization technology for its core system section, a kind of high pulse power was designed with pulse output voltage peak value of 5-30 kV (100 V stepping adjustable), adjustable output pulse frequency of 200-1 000 Hz, adjustable pulse width of 0.2-2μs, and pulse front 〈100 ns. With adjustable DC high-voltage power supply and energy-storage traveling wave tube working as its power system, this system was automatically controlled by MCU, the pulse peak value and frequency were controlled by the main discharge switch of hydrogen thyratron, and finally the pulse field was gained by pulse transformer to boost the voltage on the polar plate of sterilization cavity.
出处 《电源技术》 CAS CSCD 北大核心 2012年第5期696-698,共3页 Chinese Journal of Power Sources
关键词 高压脉冲 氢闸流管 单片机 杀菌技术 high-voltage pulse hydrogen thyratron MCU sterilization technology
  • 相关文献

参考文献4

二级参考文献14

  • 1杨绍洲,廖伟光.加速器中闸流管的原理和维护[J].医疗设备信息,2004,19(7):73-73. 被引量:5
  • 2IEEE脉冲变压器标准[J].电子变压器技术,1995(3):18-22. 被引量:1
  • 3李中友,赵东健,曲仕尧,李德刚.半桥式晶闸管弧焊逆变器变换电路原理分析[J].焊接学报,1996,17(2):104-110. 被引量:7
  • 4田新华.瓦里安CL2300C/D型直线加速器低剂量率故障应急检修一例[J].医疗设备信息,2006,21(11):107-107. 被引量:3
  • 5杨绍州,陈龙华,张树军.医用直线加速器[M].人民军医出版社.
  • 6Humberto Vega-Mercado, Olga M B, Qin B L, et al. Non-thermal food preservation: Pulsed electric fields [J]. Trends in Food Science&Technology,1997,(8):151-157.
  • 7Barsotti L, Merle P, Cheftel J C, et al. Food processing by pulsed electric fields I [J]. Physical aspects, food Rev.1999,15(2): 163-180.
  • 8Qin B L, Zhang Q, Barbosa-Canovas G V, et al. Inactivation of microor ganisms by pulsed electric fields of different voltage waveforms[J]. IEEE Trans. D&EI, 1994,(1): 1047-1057.
  • 9Jayaram S, Castel, G S P &Margaritis A. Kinetics of sterilization of lactobacillus brevis cells by the application of high voltage pulses[J]. Bio technology and Bioengineering, 1992, (40): 1412-1420.
  • 10Zimmermann U. Electrical breakdown, electropermeabilization and electrofusion[J]. Rev Phvs Biochem Pharmacol, 1986, (105): 175-256.

共引文献28

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部