摘要 在总结寒冷地区高层办公建筑的能耗特点和分析被动式节能设计中的常见问题的基础上,以西安公路研究院科研办公楼设计为例,介绍寒冷地区高层办公建筑被动式节能设计的方案,验证被动式设计的效果,最后定量地研究计算了被动式设计的节能率。 This paper summarizes the characteristics of high-rise office building energy consumption in cold areas, analyzes the common problems in passive energy-saving design. On this basis, as an example of taking the scientific research office building for Xi' an Road Institute, for example, this paper introduces the passiveenergy-saving design scheme of high-rise office building in cold areas, and verifies the effect of passive design, finally calculates quantitatively the energy-saving rate of a passive design.
出处 《工业建筑》 CSCD 北大核心 2012年第5期71-75,共5页 Industrial Construction
关键词 高层办公建筑 被动式设计 建筑节能 high-rise office building passive design building energy-saving
  • 相关文献

参考文献8

二级参考文献11

  • 1杨维菊,徐尧,吴薇.办公建筑的生态节能设计[J].建筑节能,2006(6):27-31. 被引量:21
  • 2Ziskind G, Dubovsky V, Letan R. Ventilation by natural convection of a one-story building[J]. Energy and Buildings, 2002 (34) :91-102.
  • 3Gladstone C, Woods AW. On buoyancy-driven natural ventilation of a room with a heated floor[J]. Journal of Fluid Mechanics, 2001 (441) : 293-314.
  • 4孙一坚.工业通风[M].3版.北京:中国建筑工业出版社,2002.
  • 5茅清希.工业通风[M].上海:同济大学出版社,2001.
  • 6Lomas KJ. Architectural design of an advanced naturally ventilated building form[J]. Energy and Buildings,2007(39) : 166 - 181.
  • 7Allocca C, Chen Q, Glicksman LR. Design analysis of single-sided natural ventilation [J]. Energy and Buildings, 2003 ( 35 ) : 785-795.
  • 8CIBSE. Ventilation and Air Conditioning [M]. London: Institution of Building Services Engineers ,2002.
  • 9李振翔.办公建筑节能设计方法研究[D].杭州:浙江大学,2008.
  • 10布朗GZ.太阳辐射·风·自然光--建筑设计策略[M].常志刚,刘毅军,朱宏涛,译.北京:中国建筑工业出版社,2008.