期刊文献+

高级氧化法处理硒冶炼废水的研究

Study on the treatment of selenium smelting wastewater by advanced oxidation process
下载PDF
导出
摘要 从化学键能出发,着重探讨了臭氧氧化法、Fenton氧化法处理硒冶炼废水中有机污染物的机理,并对高级氧化法进行优化组合。实验结果表明,单独使用臭氧处理废水,在酸性条件下受酯化反应的影响,加入双氧水能抑制酯化反应的进行。臭氧/H2O2+Fenton氧化法是最好的联合技术,CODCr去除率可达到88%。 Proceeding from chemical bond energy,the treatment mechanism of organic pollutants contained in selenium smelting wastewater by ozonation and Fenton oxidation is discussed emphatically. The optimized combination of the advanced oxidation is carried out. The experimental results show that when the wastewater is treated with ozone solely, it is affected by esterification reaction, under acidic conditions. Adding HEOEtO the reaction could effectively restrain esterification. However, O3/H2OE+Fenton oxidation is regarded as the best united technolo- gies. Its CODcr removing rate reaches 88%.
出处 《工业水处理》 CAS CSCD 北大核心 2012年第5期55-58,共4页 Industrial Water Treatment
基金 广东省经济和信息化委员会粤港关键领域重点突破招标项目(20100106-3) 广东省教育部产学研结合项目专项资金资助(2011B090400284) 广东省科技厅项目(2011B010100029) 广州市番禺区科技和信息化局项目(2011-专02-4-23)
关键词 高级氧化 臭氧氧化 FENTON氧化 冶炼废水 advanced oxidation process ozonation Fenton oxidation selenium smelting wastewater