天津西站地下出租车蓄车区通风系统模拟分析 被引量:2

Simulation on Ventilation System for Underground Taxi Waiting Zone in Tianjin West Railway Station
原文传递
导出
摘要 本文以天津西站交通枢纽的地下出租车蓄车区为研究对象,建立了通风系统的数学模型,并用Airpak软件对其在不同换气次数工况下的污染物及温度分布进行了模拟分析。模拟结果表明:综合考虑空气品质、舒适性以及节能运行,得到最佳换气次数为10次/h;排风口位置对空气中污染物浓度没有显著影响,受热气流影响,将排风口设置在车辆集中区域上方的排风效果更好;由于污染源种类比较单一且空气流速较大,CO和CO2的浓度分布相似。本文结论对天津西站地下出租车蓄车区通风系统设计具有一定指导意义,也可为同类型建筑的通风系统设计提供参考。 In this paper, a series of computational fluid dynamics (CFD) models were established to simulate the ventilation system of underground taxi waiting zone in Tianjin west railway station. Also steady state computational models were utilized to investigate and predict the thermal comfort and air quality under different air change rates. The results indicated that the minimum air change rate was 10 times per hour when the air quality, thermal comfort and energy-saving were comprehensively considered. Furthermore, the location of exhausts had no significant influences on air pollutant concentration. The ventilation effects were relatively better when the exhausts were located above the vehicle concentrated area. In addition, because of the limited categories of pollutant source and high speed of air flow, the concentration distributions of carbon dioxide and carbon monoxide were similar. The conclusions of this study could guide the design of ventilation system in Tianjin west railway station and other similar buildings.
出处 《建筑科学》 北大核心 2012年第6期71-77,共7页 Building Science
关键词 地下出租车蓄车区 通风系统 换气次数 空气品质 计算机数值模拟 underground taxi waiting zone ventilation system air change rate air quality numerical simulation
  • 相关文献

参考文献11

二级参考文献42

  • 1王莹,陈冬青,李小平,高德芳,孙贤,谭明.汽车尾气污染对人体健康的危害[J].中国卫生工程学,2002,1(4):204-205. 被引量:9
  • 2黎展毅,颜幼平,蔡河山.几种新型的汽车尾气净化催化剂[J].广东化工,2005,32(10):51-52. 被引量:6
  • 3金陶胜,傅立新,杜譞.吸入因子:汽车尾气污染健康影响的一种评价方法[J].环境与健康杂志,2006,23(2):182-184. 被引量:8
  • 4朱胜利.汽车尾气污染状况得到改善[N].中国环境报,2002.
  • 5周方.中外机构合作寻求汽车尾气污染解决之道[N].中国环境报,2004.
  • 6赵晖,邹林英.乌鲁木齐市汽车尾气排污现状及防治对策探讨[C].中国环境保护优秀论文集,2005.
  • 7张秀峰.光污染与人体健康[C].中国科协2000年学术年会文集,2000.
  • 8中华人民共和国卫生部.GBZ2.1-2007工作场所有害因素职业接触限值第1部分:化学有害因素[S].北京:人民卫生出版社,2007.
  • 9GB18285-2000.在用汽车排气污染物限值与测试方法[S].
  • 10AVL DIGAS 4000 LIGHT五气体分析仪操作说明书[Z].

共引文献50

同被引文献21

  • 1丁超,张旭,蒋卫艇.基于我国规范与PIARC标准的公路隧道需风量分析[J].环境工程,2011,29(S1):339-344. 被引量:4
  • 2中国建筑科学研究院.GB50736-2012民用建筑供暖通风与空气调节设计规范[s].北京:中国建筑工业出版社,2012.
  • 3Chow W K. Simulation of carbon monoxide level inenclosed car parks using an air flow network program匸J]. Tunnelling and Underground Space Technology?1996,ll(2).:237-240.
  • 4Chow W K?Won L T,Fung W Y. Field study on theindoor thermal environment and carbon monoxidelevels in a large underground car park[J]. Tunnellingand Underground Space Technology, 1996,11(3).:333-343.
  • 5Papakonstantinou K. Air quality in an undergroundgarage: computational and experimental investigationof ventilation effectiveness [ J]. Energy andBuildings,2003,35(9). :933-940.
  • 6Lin Zhang, Jiang Feng, Chow T T, et al. CFDanalysis of ventilation effectiveness in a publictransport interchange[J], Building and Environment 2006,41(3).-254-261.
  • 7Chow T T,Lin Zhang, Bai Wei. Assessment ofalternative ventilation schemes at public transportinterchange [J], Transportation Research Part D:Transport and Environment, 2006,11(6).: 447- 458.
  • 8陈在康,庄达民.气体流动数值模拟解及其在通风空调中的应用[J].湖南太学学报:自然科学版,1988,15(1).;58-65.
  • 9Etong-Uk Park, Kwon-Chul Ha. Characteristics ofPM10, PM2. 5, CO2 and CO monitored in interiorsand platforms of subway train in Seoul, Korea [J],Environment Internationa],2008,34(5). : 629-634.
  • 10WHO. Air quality guidelines for Europe [M], 2nded. Copenhagen : WHO, 2000.