摘要 配制合适比例的试金配料,不加入同位素稀释剂,熔融获得的镍扣直接用水浸泡粉化后,加入盐酸分解、过滤,沉淀物用3 mL王水溶解,定容后用ICP-MS测定,Lu作内标。采用该方法对铂族元素地球化学分析标准物质(GBW 07288、GBW 07289和GBW 07295)中的铂族元素含量进行测定,其结果与标准值相吻合。该方法检出限为0.01~0.1 ng/g,精密度(RSD,n=6)为1.67%~12.9%。 The powders were mixed with assay ingredients without isotope dilution. The nickel sulfide button was pulverized by water-dipping and then dissolved by hydrochloric acid. The solution was filtered and the precipitate was dissolved with 3 L aqua regia. In a certain constant volume platinum group elements (PGEs) in the solution were de- termined by inductively coupled plasma mass spectrometry (ICP-MS) with Lu as internal standard. The method has been verified by determination of PGEs in National Standard Referenee Materials( GBW 07288, GBW 07289 and GBW 07295) with satisfactory results. The detection limits of the method for PGEs are 0.01 -0.1 ng/g with the precision ofl.67 %-12.9 % (RSD, n=6).
出处 《黄金》 CAS 2012年第6期58-60,共3页 Gold
关键词 锍试金 电感耦合等离子体质谱法 铂族元素 化探样品 nickel sulfide assay ICP-MS PGE geochemical prospecting samples
  • 相关文献

参考文献2

二级参考文献22

  • 1石贵勇,孙晓明,王生伟,熊德信,屈文俊,杜安道.云南白马寨铜镍硫化物矿床Re-Os同位素定年及其地质意义[J].岩石学报,2006,22(10):2451-2456. 被引量:36
  • 2石贵勇,孙晓明,屈文俊,薛婷,张美,熊德信,王生伟.锍镍试金富集-等离子体质谱法测定西太平洋富钴结壳中的铂族元素[J].岩矿测试,2007,26(2):113-116. 被引量:22
  • 3孙亚莉,管希云,杜安道.锍试金富集贵金属元素1Ⅰ.等离子体质谱法测定地质样品中痕量铂族元素[J].岩矿测试,1997,16(1):12-17. 被引量:76
  • 4任静,屈文俊,刘华,杜安道.铂族元素稀释剂溶液的制备及标定[J].岩矿测试,2007,26(5):351-355. 被引量:3
  • 5Kiwamu O,Gen S,Yoshiyuki T.Quantitative Determination of Gold and Platinum-group Elements in Geological Samples Using Improved NiS Fire Assay and Tellurium Co-precipitation with Inductively Coupled Plasma Mass Spectrometry (ICPMS)[J].Chem Geol,1999,157:189-197.
  • 6Jackson S E,Fryer B J,Gosse W,et al.Determination of the Precious Metals in Geological Materials by Inductively Coupled Plasma-Mass Spectrometry (ICPMS) with Nickel Sulphide Fire Assay Collection and Tellurium Coprecipitation[J].Chem Geol,1990,83(1/2):119-132.
  • 7Paukert T,Rubeska I.Effect of Fusion Charge Composition on the Determination of Platinum Group Elements Using Collection into a Minimized Nickel Sulphide Button[J].Anal Chim Acta,1993,278(1):125-136.
  • 8Denoyer E,Ediger R,Hager J.The Determination of Precious Metals in Geological Samples by ICP-Mass Spectrometry[J].Atom Spectrosc,1987,10:97-103.
  • 9Xue Ting,Sun Xiaoming,He Gaowen,et al.Geochemistry of PGE and Au in Ferromanganese Crusts from Seamounts in the West Pacific Ocean.Mineral Deposit Research:Meeting the Global Challenge[C]//Proceedings of the Eighth Biennial SGA Meeting,2005:207-210.
  • 10Qi Liang,Zhou Mei-Fu,Christina Yan Wang.Determination of Low Concentrations of Platinum Group Elements in Geological Samples by ID-ICP-MS[J].J Anal At Spectrom,2004,19:1335-1339.