期刊文献+

70kV低剂量新技术—低剂量扫描与高质量图像的有效结合 被引量:8

70kV Low Dose Technology:Effective Combination of Low Dose CT Scan and High Quality Image
下载PDF
导出
摘要 本文介绍了70kV致微剂量超高分辨率CT扫描技术的原理,技术革新和应用,并探讨了低kV技术的相关剂量问题。70kV扫描在致微辐射剂量下,提供了超高的分辨率,是CT低剂量技术新的变革,提升了特殊病患群体的医疗服务质量。 This paper introduces the principle, technology innovation and application of the 70kV low- dose high-resolution CT scan technique. Some issuesregarding the effective dose for low tube potential CT scan are also discussed. The 70kV scan provide excellent resolution under extreme low radiation dose, which unfolds a new era for CT low dose technology innovation and improves the quality of medical service for the special patient population.
作者 张艳 袁慧书
出处 《中国医疗设备》 2012年第5期144-147,共4页 China Medical Devices
关键词 计算机断层扫描 低剂量 高分辨率 CT low dose high resolution
  • 相关文献

参考文献30

  • 1Mettler FA Jr, et al.CT scanning: patterns of use and dose[J]. J Radiol Prot, 2000(4):353-361.
  • 2Brenner DJ,et al.Computed tomography:an increasing source ofradiation exposure[J].N Engl J Med,2007(9):2277-2284.
  • 3Singh S,et al.Pointers for optimizing radiation dose in pediatric CT protocols.J Am Coil Radiol[J],2012,9(1):77-79.
  • 4Zondervan RL,et al.Frequent Body CT Scanning of Yong Adults:Indications,Outcomes,and Risk for Radiation-Induced Cancer[J].J Am Coil Radiol,2011,8(7):501-507.
  • 5Mahesh M.Advances in CT technology and application to pediatric imaging[J].Pediatr Radiol,2011,41(9):493-497.
  • 6Kalra MK,et al.Strategies for CT Radiation Dose Optimization[J]. Radiology,2004,230(3):619-628.
  • 7Ketelsen D,et al.Automated Computed Tomography DoseSaving Algorithm to Protect Radiosensitive Tissues:Estimation of Radiation Exposure and Image Quality Corisiderations[J].Invest Radiology,2012,47 (2): 148 - 152.
  • 8Wang J,et al.Bismuth Shielding,Organ-based Tube Current Modulation,and Global Reduction of Tube Current for Dose Reduction to the Eye at Head CT[J].Radiology, 2012,262(1):191-198.
  • 9Wang J,et al.Radiation dose reduction to the breast in thoracic CT:Comparison of bismuth shielding,organ-based tube current modulation,and use of a globally decreased tube current[J].Med. Phys.2011,38(11) :6084-6093.
  • 10Hu XH,et al.R.adiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space[J]. Clinic al Radiology,2011,66 ( 11 ): 1023 - 1029.

同被引文献47

  • 1刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 2任庆云,李敬玉,段雪艳.降低毫安秒对新生儿头颅CT质量的影响[J].中国辐射卫生,2006,15(3):277-278. 被引量:8
  • 3张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69
  • 4Brenner DJ,Hall EJ.Computed tomography-an increasing source of radiation exposure.N Engl J Med,2007,357(22):2277-2284.
  • 5Demarco J J,Cagnon CH,Cody DD,et al.Estimating radiation doses from multidetector CT using Monte Carlo simulations:Effects of different size voxelized patient models on magnitudes of organ and effective dose.Phys Med Biol,2007,52(9):2583-2597.
  • 6Takx RA,Schoepf UJ,Moscariello A,et al.Coronary CT angi-ography:Comparison of a novel iterative reconstruction with fil-tered back projection for reconstruction of low-dose CT-initial experience.Eur J Radiol,2013,82(2):275-280.
  • 7Johnson TR.Dual-energy CT:General principles.AJR Am J Roentgenol,2012,199(5 Suppl):S3-S8.
  • 8Waaijer A,Prokop M,Velthuis BK,et al.Circle of willis at CT angiography:Dose reduction and image quality-reducing tube voltage and increasing tube current settings.Radiology,2007,242(3):832-839.
  • 9HAUSLEITER J, MARTINOFF S, HADAMITZKY M, et al.Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial [J]. JACC Cardiovasc Imaging, 2010,3 (11) : 1113-1123.
  • 10FLORIAN F, BEHRENDT MD, SCHMIDT B, et al. Image Fusion in Dual Energy Computed Tomography: Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography [J]. Investigative Radiology, 2009,44( 1 ) : 1-7.