摘要
在原A102焊条药皮配方的基础上,改进药皮配方,研制的A102焊条与原A102焊条各项工艺性能对比试验研究的结果表明,研制的A102焊条除飞溅率稍大,其它工艺性能均优于原A102焊条.
Coating prescription is improved based on former A102 electrode. The new madr electrode has better usabilities. Except larger spatter loss coefficient, other usabilities including the arc stability, the ability of reignition, detachability, melting coefficjent, fluidity of the slag, the appearance of weld, and the degree of coating redden are all better than those or former A102 electrode.
出处
《沈阳工业大学学报》
CAS
2000年第1期8-10,共3页
Journal of Shenyang University of Technology