期刊文献+

环形腔振动敏感度的研究 被引量:1

Study on the vibrational susceptibility of the ring cavity
原文传递
导出
摘要 为了降低环形腔的环境振动敏感度,设计了一个四柱支撑环形腔。利用有限元数值模拟的方法,通过改变支柱的支撑位置和支柱直径,对环形腔进行数值模拟,得到了环形腔光程变化量随各参数变化的关系曲线。结果表明,通过选择适当的支撑位置和支柱直径,可以使得光程变化量趋近零,光程对振动不敏感。该方法对于高稳定环形腔的设计具有重要的指导意义。 In order to decrease vibrational susceptibility of the ring cavity produced by environmental vibration a ring cavity supporting with four posts is designed. Based on the finite element numerical analysis, the ring cavity is analyzed by varying the relevant parameters. The curves of optical length changes with each parameter are got. The results show that optical length changes of the ring cavity are near zero and optical length is not sensitive to vibration by optimizing supporting position and post diameter. It has the important guiding significance to the actual construction of the high sta- bility of the ring cavity.
出处 《光学技术》 CAS CSCD 北大核心 2012年第3期332-335,共4页 Optical Technique
基金 上海工程技术大学校基金项目(2009xy21)
关键词 激光技术 环形腔 数值分析 光程 laser techniques ring cavity numerical analysis optical length
  • 相关文献

参考文献3

二级参考文献23

  • 1李健,刘杰.高反射率测量中的模式匹配与谐振腔设计[J].山东师范大学学报(自然科学版),1996,11(1):20-23. 被引量:4
  • 2[5]N. Uehara,K. Ueda. Accurate measurement of ultralow loss in a high-finesse Fabry-perot interferometer using the frequency response functions.Appl.Phys.B,1995,61(1):9~15.
  • 3Boucher R, Villeneuve B, Breton M. Calibrated Fabry-Perot etalon as an absolute frequency reference for OFDM communications[J]. IEEE Photon Technol. Lett. , 1992, 4 (7) : 801- 804.
  • 4Han J. et al. Performance of Fabry-Perot microcavity structures with corrugated diaphragms[J].Sensors and Actuators, 2000, A79:162-172.
  • 5Hoogerland M D. et al. Bright thermal atomic beams by laser cooling:Ar 1400-fold gain in beam flux[J].ApPlied Physics B. 1996, 62: 323.
  • 6Mccelland J J, ErsonW R. Nanofabrication via atom optics with chromium [J].SPIE, 1997,2995: 90-95.
  • 7Zhao M,Li F S,Wang Z S, et al. Design of a frequency stabilization system using polarization spectrum in Cr atom lithography [J]. SPIE, 2005,5962,596231:1-7.
  • 8Correia J H, et al. Bulk-micromachined tunable Fabry-Perot micro-interferometer for the visible spectral range[J].Sensors and Actuators, 1999,A76 : 191-196.
  • 9Drever R W P, Hall J L, Kowalski F V, Hough J, Ford G M, Munley A J and Ward H 1983 Appl. Phys. B 31 97
  • 10Young B C, Cruz F C, Itano W M and Bergquist J C 1999 Phys. Rev. Lett. 82 3799

共引文献9

同被引文献5

  • 1Young B C,Cruz F C,Itano W M,et al.Visible lasers with subhertz linewidths[J].Phys.Rev.Lett.1999(82):3799-3802.
  • 2Oskay W H,Diddams S A,Donley E A,et al.Single-atom optical clock with high accuracy[J].Phys.Rev.Lett.2006(97):020801.
  • 3Willke B,Danzmann K,Frede M,et al.Stabilized lasers for advanced gravitational wave detectors[J].Class.Quantum Grav.2008(25):114040.
  • 4Rosenband T,Hume D B,Schmidt P O,et al.Frequency ratio of Al+and Hg+single-ion optical clocks;metrology at the 17th decimal place[J].Science,2008(319):1808-1812.
  • 5刘敏,崔小虹,钱进.利用稳频激光稳定F-P腔腔长的研究[J].光学技术,2010,36(3):361-364. 被引量:4

引证文献1