期刊文献+

基于声共振原理的管道长度测量仪 被引量:3

Pipeline length measurement based on sound resonance
下载PDF
导出
摘要 利用平面声波在管内形成驻波,根据管口声阻抗公式推导了驻波发生时相邻共振频率之差与管道长度的定量关系,利用自制装置实现了管道(直管、弯管)长度的测量,测量误差均在1.5%以下. Based on the standing wave formed in the pipeline, the relation of the pipeline length and the difference between the adjacent resonant frequencies was derived from acoustic impedance formula of pipeline end. Then the length of the pipeline was determined using microcontroller. The instrument could measure the length of both straight pipeline and bend pipeline. The test results showed that the relative errors were less then 1.5%.
出处 《物理实验》 2012年第5期28-30,共3页 Physics Experimentation
关键词 驻波 共振频率 管道长度 standing wave resonant frequency pipeline length
  • 相关文献

参考文献7

二级参考文献24

共引文献12

同被引文献30

  • 1范理,王本仁,金滔,张淑仪.谐振管谐振频率计算方法的研究[J].声学学报,2005,30(5):409-414. 被引量:6
  • 2孙渝生,张自栋,赵建新,范丽娟.激光在线长度测量仪[J].应用激光,1996,16(1):17-18. 被引量:1
  • 3娄淑琴,孙君曼.激光长度测量的研究[J].郑州轻工业学院学报,1997,12(1):18-21. 被引量:3
  • 4梁法库,吴建波,孟庆伟,崔全领.气体火焰驻波演示实验的理论分析[J].物理实验,2007,27(10):40-41. 被引量:9
  • 5Budenkov G A,Pryakhin A V,Strizhak V A.Device for detecting the liquid level in the annular space[J].Russian Journal of Nondestructive Testing,2003,39(9):654-656.
  • 6Mccoy J N,Rowlan O L.Acoustic liquid level testing of gas wells[C].SPE 120643,2009.
  • 7Terzic E,Nagarajah C R,Alamgir M.Capacitive sensorbased fluid level measurement in a dynamic environment using neural network[J].Engineering Applications of Artificial Intelligence,2010,23(4):614-619.
  • 8Sengupta D,Sai Shankar M,Saidi Reddy P,et al.Sensing of hydrostatic pressure using FBG sensor for liquid level measurement[J].Microwave and Optical Technology Letters,2012,54(7):1679-1683.
  • 9Peat K S.Acoustic impedance at the interface between a plain and a perforated pipe[J].Journal of Sound and Vibration,2010,329(14):2884-2894.
  • 10罗治安,段永法.??用旋转矢量图分析驻波特征(J)物理通报. 1997(10)