期刊文献+

HIV-1电化学活性-非活性开关分子信标的构建及验证

The construction and confirmation of HIV-1 electrochemically active-inactive switching molecular beacon
下载PDF
导出
摘要 目的构建人类免疫缺陷病毒1型(HIV-1)电化学活性-非活性开关分子信标(CAs-MB)并验证其结构及功能。方法合成并纯化针对HIV-1 gag基因保守区序列的CAs-MB,用傅里叶变换红外光谱(FT-IR)和循环伏安法(CV)验证其结构,用差分脉冲伏安法(DPV)信号强度评价CAs-MB的识别功能。结果胭脂红酸(CA)单体与CAs-MB FT-IR图的变化证明CA已标记于MB末端,CV图证明CAs-MB电化学活性ON和OFF状态的存在。DPV结果证实其能够在电化学平台上实现对目标序列的特异性识别,且能够区分一个碱基的差异。结论 CAs-MB作为HIV-1 gag基因的特异性识别元件有望用于构建新型HIV-1电化学基因传感器。 Objective To construct human immunodeficiency virus-1 (HIV-1) electrochemically active-inactive switching molecular beacon (CAs-MB) and confirm its structure and function. Methods CAs-MB targeted conserved region of HIV-1 gag gene was prepared and purified. The structure was confirmed by Fourier transform-infrared spectroscopy (FF-IR) and cyclic voltmnmetry (CV), while its function of recognizing targets was evaluated by differential pulse vohammetry (DPV). Results The variations of FF-IR spectra of free carminicacid (CA) and CAs-MB indicated that CA had covalently linked onto the ends of MB. The results of CV proved that both ON and OFF statuses of CAs-MB were existing. DPV results illustrated that CAs-MB was effective in signaling the presence of complementary target and discriminating targets in electrochemical gene biosensor that differ by a single nucleotide. Conclusions CAs-MB opens a new detective technique and can be expanded to electrochemical gene biosensor to perform HIV-1 gag gene specificity detection.
出处 《检验医学》 CAS 2012年第5期408-411,共4页 Laboratory Medicine
基金 广东省科技计划国际合作项目(2008A050200006) 广东省科技计划项目(2010A030300006) 广东省自然基金项目(S2011010003840) 国家质检总局科技计划项目(2011IK142)
关键词 人类免疫缺陷病毒1型 分子信标 电化学基因传感器 Human immunodeficiency virus-l Molecular beacon Electrochemical gene biosensor
  • 相关文献

参考文献13

  • 1郑磊,贾立永,干宁,王前.人免疫缺陷病毒感染的实验室检测及进展[J].分子诊断与治疗杂志,2010,2(4):284-288. 被引量:5
  • 2Caygill RL, Blair GE, Millner PA. A review on viral biosensors to detect human pathogens [ J]. Anal Chim Acta,2010,681 (1-2) :8-15.
  • 3Murphy JN, Cheng AK, Yu HZ, et al. On the nature of DNA self-assembled monolayers on Au: measuring surface heterogeneity with electrochemical in situ fluorescence microscopy[Jl. J Am Chem Soc,2009, 131 ( 11 ) :4042-4050.
  • 4Chomean S, Potipitak T, Promptmas C, et al. Quartz crystal microbalance-based biosensor for the detection of o~-thalassemia 1 ( SEA deletion) [ J ]. Clin Chem Lab Med, 2010,48 (9) : 1247-1254.
  • 5Su Q, Xing D, Zhou X. Magnetic beads based rolling circle amplification-electrochemiluminescence assay for highly sensitive detection of point mutation. [ J ]. Biosens Bioelectron ,2010,25 ( 7 ) : 1615-1621.
  • 6Wang S, Yang H, Zhang H, et al. A surface plasmon resonance-based system to genotype human papillomavirus [ J ]. Cancer Genet Cytogenet, 2010, 200(2) :100-105.
  • 7Pohlmann C, Sprinzl M. Electrochemical detection of microRNAs via gap hybridization assay [ J ]. Anal Chem ,2010,82 ( 11 ) :4434--4440.
  • 8李博,郑磊,王前,贾立永.电化学DNA生物传感器设计及在医学检验中的应用进展[J].分子诊断与治疗杂志,2011,3(1):46-50. 被引量:9
  • 9Zhang M, Yin BC, Tan W, et al. A versatile graphene- based fluorescence " on/off" switch for multiplex detection of various targets [ J ]. Biosens Bioelectron, 2011,26 (7) : 3260-3265.
  • 10Radi AE, Acero Sainchez JL, Baldrich E, et al. Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor [ J ]. J Am Chem Soc, 2006,128 ( 1 ) : 117-124.

二级参考文献49

  • 1艾滋病诊疗指南[J].中国感染与化疗杂志,2006,6(4):265-279. 被引量:42
  • 2干宁,李天华,陈妮,葛从辛,徐伟民.HIV-p24抗原的电化学免疫传感器研究[J].精细化工,2007,24(3):269-272. 被引量:4
  • 3中国艾滋病疫情呈4特点性传播成为主要传播途径[EB/OL].搜狐网,http://gongyi.sohu.com/20091130/n268582939.shtml,2009-11-30.
  • 4谷鸿禧.逆转录病毒[EB/OL].哈尔滨医科大学微生物学网络课程.http://www.hrbmu.edu.cn/wlkj/HMU_Microbiol/index_Textbook_33_PathogenicViruses_06.html.20084-28.
  • 5Pink R,Simek J,Vondrakova J,et al.Saliva as a diagnostic medium[J].Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub,2009,153(2):103-110.
  • 6Niederhauser C,Strohle A,Stolz M,et al.The risk of a second diagnostic window with 4th generation HIV assays:two cases[J].J Clin Virol,2009,45(4):367-369.
  • 7Garrido C,Zahonero N,Corral A,et al.Correlation between human immunodeficiency virus type 1 (HIV-1)RNA measurements obtained with dried blood spots and those obtained with plasma by use of nuclisens easyQ HIV-1and Abbott RealTime HW Load Tests[J].J Clin Microbiol,2009,47(4):1031-1036.
  • 8Chomean S, Potipitak T, Promptmas C, et al. Quartz crystal microbalance-based biosensor for the detection of alphathalassemia 1 (SEA deletion)[J]. Clin Chem Lab Med, 2010, 48(9): 1247-1254.
  • 9Su Q, Xing D, Zhou X. Magnetic beads based rolling circle amplification-electrochemiluminescence assay for highly sensitive detection of point mutation[J]. Biosens Bioelectron, 2010, 25(7): 1615-1621.
  • 10Wang S, Yang H, Zhang H, et al. A surface plasmon resonance- based system to genotype human papillomavirus[J]. Cancer Genet Cytogenet, 2010, 200(2): 100-105.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部