摘要 对国华太仓发电有限公司(太仓电厂)2×600MW机组SCR烟气脱硝失活催化剂进行分析发现,CaSO4及SiO2等杂质的堵塞是导致SCR催化剂失活的主要原因。采用超声波化学清洗、活性负载、干燥煅烧等工艺对失活催化剂进行再生后,催化剂活性大幅提高,在330℃、空速45 000h-1的条件下,再生后的催化剂对NO的转化率由40.7%提高至94.1%。 The activity lost catalysts in SCR flue gas denitrification system of 2×600 MW units in Guo- hua Taicang Power Generation Co Ltd, have been analysed,it is found that the main cause leading to activity loss of SCR catalysts is blockage due to foreign matters like CaSO4 and SlOe etc,the activity lost catalysts have been regenerated by using process of ultrasonic chemical cleaning, active load, and drying incineration etc. , the activity of catalysts after regeneration has been greatly enhanced, under condition of temperature 330 ℃ and air speed 45 000^-1 , the catalysts after regeneration can make the transform rate of NO to rise from 40.7% to 94.1%.
出处 《热力发电》 CAS 北大核心 2012年第5期95-98,共4页 Thermal Power Generation
基金 广东省高新技术产业化项目资助(2011B010100030)
关键词 SCR 脱硝 催化剂 活性 清洗 再生 SCR denitrification catalyst activity cleaning regeneration
  • 相关文献

参考文献6

  • 1强华松,刘清才.燃煤电厂SCR脱硝催化剂的失活与再生[J].材料导报(纳米与新材料专辑),2008,22(3):285-287. 被引量:32
  • 2Fushun Tang,Bolian Xu.The poisoning effect of Na+ and Ca2+ ions doped on the V2O5/TiO2 catalysts for selective catalytic reduction of NO by NH3[J].Appl.Catal.B,2010,94(1):71-76.
  • 3朱崇兵,金保升,仲兆平,李锋,陈玲霞,翟俊霞.K2O对V2O5-WO3/TiO2催化剂的中毒作用[J].东南大学学报(自然科学版),2008,38(1):101-105. 被引量:32
  • 4Yuanjing Zheng.Deactivation of V2O5,-WO3-TiO2 SCR catalyst at a biomass-fired combined heat and power plant[J].Appl.Catal.B,2005,60(1):253-264.
  • 5孙克勤,钟秦,于爱华.SCR催化剂的碱金属中毒研究[J].中国环保产业,2007(7):30-32. 被引量:36
  • 6李忠,郭建光,奚红霞,等.超声-等离子体联合CuO/CeO2/g-Al2O催化剂的方法[P].中国,ZL 200610036797.6,2008-8-20.