期刊文献+

Comparison of RFFIT Tests with Different Standard Sera and Testing Procedures 被引量:6

Comparison of RFFIT Tests with Different Standard Sera and Testing Procedures
下载PDF
导出
摘要 The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation. The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, Sl, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation
出处 《Virologica Sinica》 CAS CSCD 2012年第3期187-193,共7页 中国病毒学(英文版)
基金 Grant from National Institute of Infectious Diseases(NIID) National Department Public Benefit Research Foundation (201103032)
关键词 血清样品 标准试验 测试程序 试验比较 中国疾病预防控制中心 世界卫生组织 抗体滴度 实验室 Rapid fluorescent focus inhibition test (RFFIT) Standard serum Neutralizing antibody Titer
  • 相关文献

参考文献3

二级参考文献15

  • 1严家新,潘南胜.狂犬病流行简史[J].中华医史杂志,1994,24(4):196-199. 被引量:8
  • 2严家新.狂犬病毒分子流行病学研究进展[J].国外医学(病毒学分册),1995,2(2):34-37. 被引量:5
  • 3WHO.WHO Expert Consultation on Rabies.WHO technical report series,No.931.Geneva:WHO,2004.
  • 4Coleman PG,Dye C.Immunization coverage required to prevent outbreaks of dog rabies.Vaccine,1996,14(3):185-186.
  • 5WHO.WHO Export Committee on Rabies WHO technical report series,No.824.Geneva:WHO,1992.
  • 6WHO.WHO Expert Committee on Biological Standardization,1988,Thirty-eighth Report;WHO technical report series No.771.Geneva:WHO,1988.
  • 7Fitzgerald EA,Cabasso VJ,Smith JS,et al.A collaborative study oil the testing of rabies immune globulin(human)by the mouse neutralization test(MNT)and a rapid fluorescent focus inhibition test(RFTIT).J Biol Stand,1979,7(1):67-72.
  • 8Péharpré D,Cliquet F,Sagné E,et al.Comparison of visual microscopic and computer-automated fluorescence detection of rabies virus neutralizing antibodies.J Vet Diagn Invest,1999,11(4):330-333.
  • 9Khawplod P,Inoue K,Shoji Y,et al.A novel rapid fluorescent focus inhibition test for rabies virus using a recombinant rabies virus visualizing a green fluorescent protein.J Virol Methods,2005,125(1):35-40.
  • 10World Health Organization.World survey of rabies no.35 for the year 1999.WHO/CDS/CSR/EPH/2002.10,Geneva.

共引文献35

同被引文献23

引证文献6

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部