摘要 目的探讨藻酸盐印模在非密封或密封状态下放置不同时间对尺寸稳定性的影响。方法实验分为藻酸盐印模非密封10min组4、0min组和80min组,藻酸盐印模密封10min组、40min组和80min组,另设1组空白对照。分别用普通石膏、硬石膏和超硬石膏制取模型,电子数显卡尺测量标准实物及石膏模型尺寸,进行ANOVA比较(α=0.05)。结果在藻酸盐印模非密封10min、40min和80min三组中,普通石膏、硬石膏和超硬石膏所灌注的模型尺寸表现为逐渐增加的趋势;在藻酸盐印模密封10min4、0min和80min三组中,三种石膏模型尺寸变化表现为先减小后增大的趋势。各组间存在显著性差异(P<0.05)。结论随放置时间的延长,藻酸盐印模在非密封和密封不同状态下,可发生不同的印模尺寸变化。 Objective To observe the size stability of alginate impression under sealed and non - sealed condi- tions. Methods A blank group and six experimental groups included: 10min sealed group, 10rain non - sealed group, 40rain sealed group, 40min non - sealed group, 80rain sealed group and 80rain non - sealed group. Impressions were poured by using common gypsum, anhydrite gypsum and ultrahard gypsum, respectively. The measured data were used to carry out ANOVA ( α = 0.05). Results Size of sealed groups took on expansive tendency, but non - sealed groups took on decreasing tendency firstly and expansive tendency followed ( P 〈 0.05 ). Conclusions Alginate impression took on different size stability under sealed and non - sealed conditions because of permeation and syneresis mechanism.
出处 《口腔材料器械杂志》 2012年第2期77-79,共3页 Chinese Journal of Dental Materials and Devices
基金 浙江省教育厅基金(N20110143) 浙江大学SRTP教师立项(6184)
关键词 藻酸盐印模 石膏模型 尺寸稳定性 Alginate impression Gypsum model Size stability
  • 相关文献

参考文献8

二级参考文献20

  • 1夏勇,黄翠.3种印模材料制取活动义齿模型的三维精度比较[J].口腔医学研究,2004,20(5):514-516. 被引量:4
  • 2孙惠强,梁星,包向军,宋宏杰,胡建.自制个别取模器颈缘取模技术精确度的研究[J].口腔颌面修复学杂志,2005,6(2):132-134. 被引量:4
  • 3顾斌,马轩祥,刘杰.超硬石膏材料水粉比对模型精度和表面硬度的影响[J].口腔颌面修复学杂志,2005,6(4):290-292. 被引量:10
  • 4郭华,徐忠建.调合消毒法对藻酸盐印模材消毒效果的研究[J].口腔医学研究,2006,22(2):169-171. 被引量:14
  • 5Ceyhan JA, Johnson GH, Lepe X. The effect of tray selection, viscosityof impression material, and sequence of pour on the accuracy of dies made from dual-arch impression[J]. J rosthet Dent, 2003, 90(2): 143-149.
  • 6Abdullah MA. Surface detail, compressive strength, and dimensional accuracy of gypsum casts after repeated immersion in hypochlorite solution[J]. J Prosthet Dent, 2006, 95 (6): 462-468.
  • 7S. Y. Chen, W.M.Liang, F.N. Chen. Factors affecting the accuracy of elastometric impression materials [J]. Journal of Dentistry, 2004, 32(8): 603-609.
  • 8N.Martin. The dimensional stability of dental impression materials following immersion in disinfecting solutions [J]. Dental Materials, 2007, 23 : 760-768.
  • 9Al-Jabrah O,Al-Shumailan Y,Al-Rashdan M.Antimicrobial effect of 4 disinfectants on alginate,polyether,and polyvinyl siloxane impression materials[J].Int J Prosthodont,2007,20(3):299-307.
  • 10Bergman B.Disinfection of prosthodontic impression materials:a literature review[J].Int J Prosthodont,1989,2(6):537-542.

共引文献29

同被引文献35

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部