摘要
通过对中石油独山子石化分公司乙烯厂乙二醇(6万吨EO/EG)装置的干燥塔釜液泵P-610A/B结焦周期短、检修频次高的原因进行分析并提出改进措施,延长结焦周期、降低检修维护的成本和频次。
The cause of coking,short coking cycle and high frequency maintenance for drying column bottom pump P-610A/B of Ethylene Glycol plant(EO/EG) was analyzed,and some measures were proposed to extending the coking cycle,reducing maintenance cost and frequency for improvement.
出处
《广州化工》
CAS
2012年第10期145-146,179,共3页
GuangZhou Chemical Industry
关键词
离心泵
结焦
机械密封
清焦
centrifugal pump
coking
mechanical seal
de-coking