摘要 利用自主研制的波场采油动态模拟实验装置,对人工岩心聚合物堵塞样品开展了超声波解除岩心聚合物堵塞实验研究,评价了超声波解除岩心聚合物堵塞的整体效果,分析了波场参数、工艺参数、储层物性参数对超声波解除聚合物堵塞的影响规律,并将超声波、化学剂、超声波—化学剂复合解堵效果进行了对比。实验结果表明:超声波功率、频率、处理时间、岩心初始渗透率等参数均能影响超声波解堵效果;超声波功率越大,解堵效果越好;超声波频率高,能量衰减快,解堵效果变差;最佳累积处理时间为80~100 min;岩心气测渗透率增加,解堵效果变差;超声波—化学剂复合解堵效果最好。 By means of the self-developed dynamic simulation experimental apparatus of fluctuating oil extraction technology and the artificial cores plugged by polymer,the effect of ultrasonic treatment and the influence rules of ultrasonic parameters,process parameters and core physical parameters on the results of ultrasonic treatment for removal of near wellbore polymer damage are studied.Furthermore,the results of ultrasonic treatment,chemical treatment and composite treatment are compared.The study results show that the ultrasonic frequency,ultrasonic power,ultrasonic processing time and core permeability can influence the plugging removal effect.The plugging removal effect obtains better performance with the increment of ultrasonic power.The performance is poor with the increment of ultrasonic frequency and initial permeability of the cores.The optimized ultrasonic processing time is 80-100 min,and the result of composite treatment is the best.
出处 《油气地质与采收率》 CAS CSCD 北大核心 2011年第5期93-96,117,共4页 Petroleum Geology and Recovery Efficiency
基金 国家"863"计划目标导向重大课题"超大功率超声波油井增油技术及其装置研究"(2007AA06Z227) 国家科技重大专项课题"复杂油气田地质与提高采收率技术"(2009ZX05009)
关键词 超声波 近井带 聚合物堵塞 室内实验 复合解堵 ultrasonic near wellbore zone polymer plugging experimental study composite unplugging treatment
  • 相关文献

参考文献11

二级参考文献71

共引文献126

同被引文献56

引证文献8

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部