摘要 目的了解深圳市某区中小学教室空气可吸入颗粒物状况,为改善中小学教学环境卫生状况提供科学依据。方法分层抽取深圳市某区19所中小学114个教室,采用DUSTMATE环境粉尘仪对PM 10,PM 2.5,PM 1.0进行检测。结果 PM 10最大值为0.418mg/m3,超出国家标准1.79倍;PM 2.5最大值为0.142 mg/m3,超出美国EPA新标准3.06倍;PM 1.0最大值为0.056 mg/m3。工业区中小学教室PM 10,PM 2.5,PM 1.0含量高于商业区和居民区,差异均有统计学意义(P值均<0.05)。小学教室PM 10、PM 2.5合格率均高于中学教室;教室PM 10,PM 2.5含量随着楼层增加而下降,差异均有统计学意义(P值均<0.05)。结论深圳市某区中小学教室颗粒物PM 10,PM 2.5,PM 1.0污染情况严重,应引起高度重视并采取综合控制措施。 Objective To investigation the indoor air PM10, PM2.5, PM1.0 of primary and middle Schools in Shenzhen, and provide scientific basis for the government to development relevant health policies, improving the teaching environment and health condition. Methods Stratified sampling method was adopted to select 89 classrooms from 11 kindergartens in a district of She nzhen , the level of PM10, PM2.5, PM1.0 were meas- ured by field monitoring equipment. Results The maximum of PM10 was 0. 396mg/m3 which was over 1.64 times of national standard. The maxi- mum of PM2.5 was 0. 137 mg/m3 , over 2.91 times of the standard of American EPA ( 2006 updated }. The maximum level of PM1.0 was 0. 063rag/ m3. The level of indoor air PM10, PM2.5, PM1.0 in industrial estate schools were much higher than those in residential and trading area{ P〈0.05 }. The normal percent of indoor air PM10, PM2.5 in primary Schools were higher than those in middle school ; and the level of PM 10, PM 2.5 decline with storey rising. Conclusion In study district, the environmental problems of indoor air PM 10, PM 2.5 and PM 1.0 of school must be paid e- nough attention to, and it is necessary to took comprehensive measures to protect the health of children.
出处 《中国学校卫生》 CAS 北大核心 2012年第5期572-574,共3页 Chinese Journal of School Health
关键词 颗粒物 空气污染 室内 学生保健服务 Particulate matter Air pollution ,indoor Student health services
  • 相关文献

参考文献12

  • 1SCHWARTZ J, NEAS LM. Fine particles are more strongly asso-ciated than coarse panicles with acute respiratory health elfeets in school- children [ J ]. Epidemiology, 2000,11 ( 1 ) :6-10.
  • 2BECHTEL DG, WALDNER CL, WICKSTROM M. Associations between immune function in yearling beef cattle and airborne polycyclic aromatic hydrocarbons and PM1.0 near oil and natural gas field facilities[ J]. Arch Environ Occup Health, 2009,64( 1 ) :47-58.
  • 3国家技术监督局,中华人民共和国卫生部.公共场所卫生监测技术规范(GB/T17220-1998)[S].北京:中国标准出版社,1998.
  • 4国家质量监督检验检疫总局,卫生部,国家环境保护总局.室内空气质量标准(GB/T18883-2002)[S].北京:中国标准出版社,2003.
  • 5ENGEL-COX JA, WEBER SA. Compilation and assessment of recent positive matrix factorization and UNMIX receptor model studies on fine particulate matter source apportionment for the eastern United States [J]. J Air Waste Manag Assoc, 2007,57(11) :1307-1316.
  • 6赵鑫,林刚,杜莹.大气颗粒物污染对儿童健康的影响[J].中国学校卫生,2008,29(11):1067-1069. 被引量:7
  • 7邓芙蓉,王欣,苏会娟,吴少伟,吕海波,郭新彪.北京市某城区儿童大气PM2.5个体暴露水平及影响因素研究[J].环境与健康杂志,2009,26(9):762-765. 被引量:26
  • 8JANICE JK, SVETLANA S, MICHAEL L, et al. Traffic-related air pollution near busy roads: The east bay children's respiratory health study[J]. Am J Res Critical Care Med, 2004,170(5) :520-526.
  • 9ADRIAN GB, GAIL MW, JOEL S, et al. Air pollution and child respiratory health: A case-crossover study in Australia and New Zealand [ J ]. Am J Res Critical Care Med, 2005,171 ( 11 ) :1272-1278.
  • 10GOYAL R, KHARE M. Indoor air quality modeling for PM 10, PM 2.5, and PM 1.0 in naturally ventilated classrooms of an urban Indian school building[ J]. Environ Monit Assess, 2011,176 ( 1-4 ) : 501 - 516.