期刊文献+

A^2/O^2工艺处理焦化废水工程实践 被引量:4

THE PRACTICE OF COKING WASTEWATER WITH A^2/O^2 PROCESS
下载PDF
导出
摘要 印度JSW钢厂焦化废水处理工程,在设计水力停留时间短的情况下,原水不稀释直接生化处理。经过近3个月的调试、运行,出水均可达到设计标准:COD为140~210 mg/L(设计值250 mg/L),去除率大于91%;氨氮质量浓度小于10 mg/L(设计值50 mg/L),去除率大于97%;运行成本较国内类似项目节省3~5元/m3。 JSW coking wastewater project in India treated with biochemical directly no dilution on condition that design HRT is short. After 3 months of commissioning and running, the effluents meet the design standard. The effluent COD fluctuated between 140 and 210 mg/L, the removal rate is more than 91%, and effluent ammonia is less than 10 mg/L, the removal rate is more than 97%. The cost of running could save between 3 and 5 yuan per ton wastewater compared with the local similar projects.
出处 《水处理技术》 CAS CSCD 北大核心 2012年第6期123-125,共3页 Technology of Water Treatment
关键词 焦化废水 生化处理 调试 运行 coking wastewater biochemical treatment commissioning running
  • 相关文献

参考文献4

  • 1国家环保局.钢铁工业废水处理[M].北京:中国环境科学出版社,1992,77-80.
  • 2Min Zhang, Joo Hwa Tay, Yi Qian. et al. Coke plant wastewater treatment by fixed biofilm system for COD and NI--I3-N removal[J]. Water research,1998,32(30):519-527.
  • 3Bridle TR, Bedford WK, Jank BE. Biological nitrogen control of coke plant wastewaters [J].Water Science & Technol.,1981,13(1): 667-680.
  • 4闵玉国,崔利平,薛英连,车彤,单明军.焦化废水处理工程调试运行研究[J].环境工程,2011,29(3):10-12. 被引量:1

二级参考文献6

共引文献3

同被引文献25

引证文献4

二级引证文献27