期刊文献+

Digital discrimination of neutrons and γ rays with organic scintillation detectors in an 8-bit sampling system using frequency gradient analysis 被引量:4

Digital discrimination of neutrons and γ rays with organic scintillation detectors in an 8-bit sampling system using frequency gradient analysis
原文传递
导出
摘要 The feasibility of using frequency gradient analysis (FGA), a digital method based on Fourier transform, to discriminate neutrons and T rays in the environment of an 8-bit sampling system has been investigated. The performances of most pulse shape discrimination methods in a scintillation detection system using the time-domain features of the photomultiplier tube anode signal will be lower or non-effective in this low resolution sampling system. However, the FGA method using the frequency-domain features of the anode signal exhibits a strong insensitivity to noise and can be used to discriminate neutrons and ~/rays in the above sampling system. A detailed study of the quality of the FGA method in BC501A liquid scintillators is presented using a 5 G samples/s 8-bit oscilloscope and a 14.1 MeV neutron generator. A comparison of the discrimination results of the time-of-flight and conventional charge comparison (CC) methods proves the applicability of this technique. Moreover, FGA has the potential to be implemented in current embedded electronics systems to provide real-time discrimination in standalone instruments. The feasibility of using frequency gradient analysis (FGA), a digital method based on Fourier transform, to discriminate neutrons and T rays in the environment of an 8-bit sampling system has been investigated. The performances of most pulse shape discrimination methods in a scintillation detection system using the time-domain features of the photomultiplier tube anode signal will be lower or non-effective in this low resolution sampling system. However, the FGA method using the frequency-domain features of the anode signal exhibits a strong insensitivity to noise and can be used to discriminate neutrons and ~/rays in the above sampling system. A detailed study of the quality of the FGA method in BC501A liquid scintillators is presented using a 5 G samples/s 8-bit oscilloscope and a 14.1 MeV neutron generator. A comparison of the discrimination results of the time-of-flight and conventional charge comparison (CC) methods proves the applicability of this technique. Moreover, FGA has the potential to be implemented in current embedded electronics systems to provide real-time discrimination in standalone instruments.
出处 《Chinese Physics C》 SCIE CAS CSCD 2012年第6期544-551,共8页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China (A050508/11175254)
关键词 n-y discrimination liquid scintillator FGA 8-bit sampling system n-y discrimination, liquid scintillator, FGA, 8-bit sampling system
  • 相关文献

参考文献23

  • 1Knoll G F. Radiation Detection and Measurement. third edition. New York: Wiley, 2000.
  • 2Brooks F D. Nuch Instrum. Methods, 1959, 4:151-163.
  • 3Adams J M, White G. Nucl. Instrum. Methods, 1978, 156: 459-476.
  • 4Alexander T K, Goulding F S. Nucl. Instrum. Methods, 1961, 13:244-246.
  • 5Roush M, Wilson M A, Hornyak W F et al. Nucl. Instrum. Methods, 1964, 31:112-114.
  • 6Moszyfiski M, Costa G J, Guillaume G. Nucl. Instrum. Methods A, 1994, 350:226-234.
  • 7Jastaniah S D, Sellin P J. Nucl. Instrum. Methods A, 2004, 517:202-210.
  • 8Cerny J, Dolezal Z, Ivanov M P et al. Nucl. Instrum. Methods A, 2004, 527:512-518.
  • 9Kornilov N V, Khriatchkov V A, Dunaev M et al. Nucl. Instrum. Methods A, 2003, 497:467-478.
  • 10Marrone S, Cano-Ott D, Colonna N, Domingo C et al. Nucl. Instrum. Methods A, 2002, 490:299-307.

同被引文献16

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部