期刊文献+

MSCT低剂量扫描对腰椎图像质量影响的初步研究 被引量:3

The study of the effect on the image quality in low-dose MSCT of lumbar vertebrae
下载PDF
导出
摘要 目的探讨MSCT低剂量扫描技术(单纯降低mAs),受检者所接受辐射剂量及其对图像质量的影响。方法将120名受检者随机分成实验组(60例)和对照组(60例),两组分别采用低剂量(100mAs)和常规剂量(200mAs)进行扫描,其余参数完全相同,测量并记录两组患者的辐射剂量和图像噪声,对各组图像质量进行评价。结果两组患者所接受的辐射剂量分别为:5.72±0.32和11.45±0.76,差异有统计学意义(P<0.05),实验组所接受的剂量显著低于对照组。图像的评价结果显示:随着mAs降低,骨小梁及软组织显示略模糊,图像噪声增加,但实验组图像仍可满足临床诊断(两组图像评分分别为11.07±0.82和11.30±0.79,P>0.05)。结论单纯降低mAs的腰椎MSCT低剂量扫描技术可大幅降低辐射剂量,所获得的图像基本能满足临床诊断要求,可作为常规应用于临床,值得进一步推广应用。 Objective To determine the effect of reducing mAs on the diagnostic quality of images and the radiation dose in patients undergoing lumbar vertebrae MSCT. Methods 120 cases were divided randomly divided into two groups:expemental group (low dose group,100 mAs group, 60 cases) and control group (200 mAs group, 60 cases). The quality of imaging and radiation dose were compared among three groups. Results The CTDIvol of two groups were 5.72 ± 0.32 and 11.45±0.76, respectively. There were significant differences among three groups ( P 〈0.05). However, the quality of images between two groups was not different ( P 〉0.05), the scores of image quality between two group were 1.07± 0.82 and 11.30±0.79. Conclusion The low-dose scan mode could be used in routine examination of lumbar vertebrae using MSCT.
出处 《医学影像学杂志》 2012年第5期803-805,共3页 Journal of Medical Imaging
关键词 辐射剂量 腰椎 体层摄影术 X线计算机 Radiation dose Lumbar vertebrae Tomography, X-ray computed
  • 相关文献

参考文献11

二级参考文献31

  • 1郑钧正,贺青华,李述唐,岳保荣,王琪,杨霞,张建峰.我国电离辐射医学应用的基本现状[J].中华放射医学与防护杂志,2001,21(S1):13-20. 被引量:63
  • 2刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 3赵修义,李国英,陈静,肖红,刘汝勤.CT检查的防护探讨[J].中华放射医学与防护杂志,1995,15(1):57-57. 被引量:10
  • 4周冕.吸烟与肺癌的研究进展[J].中国肿瘤,1996,5(3):11-13. 被引量:2
  • 5Hein E, Rogalla P, Klingebiel R, et al. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose. Eur Radiol, 2002, 12:1693-1696.
  • 6Czechowski J, Janeczek J, Kelly G, et al. Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses. Eur Radiol, 2001, 11:711-713.
  • 7Kennedy DW, Zinreich SJ, Rosenbaum AE, et al. Functional endoscopic sinus surgery: theory and diagnostic evaluation. Arch Otolaryngol, 1985, 111:576-582.
  • 8Han P, Pirsig W, Ilgen F, et al. Virtual endoscopy of the nasal cavity in comparison with fiberoptic endoscopy. Eur Arch Otorhinolaryngol, 2000, 257:578-583.
  • 9Klevansky A. The efficacy of multiplanar reconstructions of helical CT of the paranasal siunses. AJR, 1999, 173: 493-495.
  • 10Hilger AW, Ingels K, Joosten F. Sagittal computerized tomography reconstruction of the lateral nasal functional endoscopic sinus surgery. Clin Otolaryngol, 1999, 24: 527-530.

共引文献283

同被引文献28

  • 1王刚,白艳,向建斯,郑树卿.眼眶部低剂量CT扫描的辐射防护[J].实用放射学杂志,2007,23(7):960-962. 被引量:15
  • 2Naidich DP, Marshall CH, Gribbin C, et al. Low-dose CT of the lungs: preliminary observations[J].Radiology, 1990, 175(3): 729-731.
  • 3Aprile I, Ottaviano I, Buono E, et al. Low-dose brain computer tomogra- phy sensitivity: a comparative study with a conventional technique [J]. Neuroradiology, 2012,25 (2) : 151-162.
  • 4Gnannt R, Winklehner A, Goetti R, et al. Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol[J]. American Journal of Neuroradiology,2012,33(6): 1014-1019.
  • 5Liu Y, Jordan W, Volkmar M. A low dose chest CT program[J]. Radiol- ogy Manage, 2012,34(3):9-10.
  • 6Funama Y. Low-dose CT and image quality[J]. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2011, 67(11) : 1461-1467.
  • 7李月卿.医学影像成像理论[M].2版.北京:人民卫生出版社,2010:183-219.
  • 8尉可道,蒋学祥.CT中的放射防护[J].中国医学影像技术,2009,25(11):2135-2139. 被引量:52
  • 9张彦彩,朱小忠,马国林,王武.螺旋CT低剂量扫描研究进展[J].中国医学影像技术,2010,26(7):1376-1378. 被引量:71
  • 10王俊山,袁东升,赵文莉,于承才,向婷,阙永盛,张平.腰椎间盘退行性病变低剂量CT扫描的临床应用[J].中国CT和MRI杂志,2010,8(4):38-41. 被引量:14

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部