期刊文献+

微创外科机器人力反馈跟踪控制 被引量:3

Haptic Tracking Control for Minimally Invasive Robotic Surgery
原文传递
导出
摘要 针对微创外科机器人(MIRS)力觉反馈缺失问题,构建了主从机器人力反馈控制系统,采用Newton-Euler法建立了力反馈机器人的动力学模型,提出了实时力反馈控制策略。实验验证了该系统及其方法的有效性,具有理论研究和临床应用价值,可用于外科机器人的远程手术。 Haptie feedback plays a significant role in minimally invasive robotic surgery (MIRS). A major deficiency of the current MIRS is the lack of haptic perception for the surgeon, including the commercially available robot da Vinci surgical system. In this paper, a dynamics model of a haptic robot is established based on Newton-Euler meth- od. Because it took some period of time in exact dynamics solution, we used a digital PID arithmetic dependent on ro- bot dynamics to ensure real-time bilateral control, and it could improve tracking precision and real-time control effi- ciency. To prove the proposed method, an experimental system in which two Novint Falcon haptic devices acting as master-slave system has been developed. Simulations and experiments showed proposed methods could give instru- ment force feedbacks to operator, and bilateral control strategy is an effective method to master-slave MIRS. The proposed methods could be used to tele-robotic system.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2012年第3期407-410,共4页 Journal of Biomedical Engineering
基金 上海市科学技术委员会基金资助项目(10PJ1407800) 上海市"东方学者基金"资助项目 上海高校选拔培养优秀青年教师科研专项基金资助项目(slgl0019)
关键词 力反馈 微创外科 主从机器人 跟踪控制 Force feedback Minimally invasive surgery Master-slave robot Tracking control
  • 相关文献

参考文献7

  • 1王国彪,彭芳瑜,王树新,朱晒红,王田苗.微创手术机器人研究进展——“微创手术机器人及器械基础理论与关键技术”双清论坛综述[J].中国科学基金,2009,23(4):209-214. 被引量:20
  • 2PALEP J H. Robotic assisted minimally invasive surgery[J]. J Minim Access Surg, 2009, 5(1): 1-7.
  • 3HATZFELD C. KERN T, WERTHSCHUTZKY A R. Design and evaluation of a measuring system for human force perception paramet[J]. Sensors and Actuators A: Physical. 2010, 162(2) : 202-209.
  • 4MARTIN S, HILLIER N. Characterisation of the novint fal- con haptic device for application as a robot manipulator [C]// In Proceedings of the Australasian Conference on Robotics and Automation. Sydney,Australia, 2009.
  • 5FUMAGALLI A, MASARATI P. P, eal-time inverse dynamics control of parallel manipulators using general-purpose multibody software[J]. Multibody Syst Dyn, 2009, 22(1): ,17-68.
  • 6LAULUSA A, BAUCHAU O A. Review of classical approaches for constraint engorcement in muhibody systems[J]. Journal of Computational and Nonlinear Dynamics, 2008, 3 (1) : 1-11.
  • 7SEPULVEDA-CERVANTES G. PARRA-VEGA V, DOMINGUEZ-RAMIREZ O A. Dynamic coupling haptic sutu- ring based on orthogonal decomposition [C]// Third Joint and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. 2009 ,182-487.

二级参考文献21

  • 1罗杨宇,朱森强,杨向东,陈恳.机器人辅助手术导航系统的空间映射方法[J].中国机械工程,2007,18(5):536-540. 被引量:5
  • 2Paolo D,Eugenio G.Robotics for Medical Applications.In:IEEE Robotics and Automation Magazine,September 1996,3(3):44-56.
  • 3Robert D Howe,Yoky Matsuoka.Robotics For Surgery.In:Division of Engineering and Applied Sciences,Harvard Uni-versity,1999.
  • 4Setava R M.Surgical Robotics:The Early Chronicles-A Personal Historical Perspective.In Surgical Laparoscopy,In:Endoscopy & Percercutaneous Techniques,Lipincott Williams & Wilkins,Inc.Philadelphia,2002,12:6-16.
  • 5Russell H Taylor.A Perspective on Medical Robotics.In:Proceeding of the IEEE,Sep,2006.
  • 6Satava R M.Surgical Robotics:The Early Chronicles-A Personal Historical Perspective.In Surgical Laparoscopy,In:Endoscopy & Percercutaneous Techniques,Lipincott Williams & Wilkins,Inc.Philadelphia,2002,12:6-16.
  • 7Menon M,Shrivastava A,Tewari A et al.Laparoscopic and Robot Assisted Radical Prostatectomy.In:Establishment of a Structured Program and Preliminary Analyses of Outcomes,2002.
  • 8McLeod I K,Mair E A,Melder P C.Potential applications of the da Vinci minimally invasive surgical robotic system in otolaryngology.In,Ear,Nose and Throat Journal,August 1,2005,84(8):483-487.
  • 9Burner S E,Ghodoussi M.A real-time system for tele-surgery.In,Proceedings 21st international Conference on Distributed Computing Systems,2001:236-243.
  • 10Ghodoussi M,Butner S E,Wang Y L.Robotic surgery the transatlantic case.In:Proceedings 2002 IEEE International Conference on Robotics and Automation,2002,2 (2):1882-1888.

共引文献19

同被引文献33

  • 1史英海,王越超.基于Internet的力反馈技术研究[J].机器人,2004,26(4):330-335. 被引量:3
  • 2闵友江,王海生,严振国,邵水全.试论传感技术在针灸推拿学中的应用与研究[J].上海针灸杂志,2006,25(12):27-29. 被引量:4
  • 3程卓,王海生,闽友江,严振国,张虹,庄天戈.数字人体的针灸力感虚拟现实初步研究[J].中国医疗器械杂志,2007,31(1):5-9. 被引量:14
  • 4杨宇航,李志忠,任晓丹,何鑫,苏曼迪.基于虚拟现实技术的中医针灸教学系统[J].系统仿真学报,2007,19(10):2379-2383. 被引量:20
  • 5Pheng-Aun Hang, Tien-Tsin Wong, Rong Yang, et al. Intelligent Inferencing and Haptic Simulation for Chinese Acupuncture Learning and Training [J]. Transactions on Information Technology in Biomedicine (S1089-7771), 2006, 10(1): 28.
  • 6Rakhsha R, Constantinescu D. Distributed haptic cooperation with passive multirate wave communications [C]// IEEE Haptics Symposium 2012, Canada. USA: IEEE, 2012: 117-123.
  • 7Kammerl J, Vittorias I, Nitsch V, et al. Perception-based data reduction for haptic force-feedback signals using adaptive deadbands [J]. M1T Press Journals, Presence: Teleoperators and Virtual Environments (S 1054-7460), 2010, 19(5): 450-462.
  • 8Lee Dong-Jun, Huang Ke. Peer-to-peer control architecture for multiuser haptics collaboration over undirected delayed packet- switching network [C]// Proc. IEEE International Conference on Robotics & Automation (ICRA). USA: IEEE, 2010: 1333-1338.
  • 9K M Yap, T H Lee. A Study to Support Haptic Collaboration with Real Time Force Feedback over Wireless Networks [C]//2011 First International Conference on Robol, Vision and Signal Processing (RVSP). USA: IEEE, 2011: 348-351.
  • 10P Brett, T Parker, A Harrison, et al. Simulation of resistance forces acting on surgical needles [J]. Proceedings of the Institute of Mechanical Engineers (S0954-4119), 1997, 211 (4): 225-347.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部