摘要
根据现有的数据和资料 ,对变电站的电磁现象及其骚扰源的强度和特性进行分析 ;确定继电保护设备所应进行的电磁抗扰度试验及抗扰性能 ,得出这类设备应用于高压变电站开关场地时 。
Based on some of the data and information, this paper analyzes the intensity and charactristic of the EM phenomena and their sources in the HV substation. It also presents the immunity tests for the relaying equipment and then confirms the immunity of the equipment. The protection measures of the equipment used in the switchyard in HV substation is found.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2000年第1期16-18,共3页
High Voltage Engineering
关键词
变电站
电磁骚扰
继电保护设备
抗扰度
substation electromagentic disturbance relaying equipment immunity