摘要
设计了电磁抑垢实验平台,理论计算验证了模拟换热器实验管道壁温测量值的准确性。并通过实验对电导率比差值曲线进行分析,说明电导率对电磁抑垢效果所产生的影响。
An electromagnetic anti-scaling experimental platform was designed, and though theoretical calculation and experiment, the accuracy of simulating heat pipe wall temperature measurement was verified and the conductivi- ty ratio-difference curve was analyzed to explain conductivity' s influence on electromagnetic anti-scaling.
出处
《化工自动化及仪表》
CAS
2012年第6期761-764,共4页
Control and Instruments in Chemical Industry
基金
国家自然科学基金资助项目(51176028)
吉林省自然科学基金资助项目(201115179)
关键词
污垢热阻
管道壁温
电导率
抑垢效果
fouling resistance, pipe wall temperature, electrical conductivity, anti-scaling effect