结合火炬塔架的设计,根据相关设计规范及资料,介绍了两种不同形式截面的抗剪键的设计方法,并进行了分析计算,对其结果进行了比较,以达到优化设计的目的。
Combining with the design for the torch tower, the study introduces the two design methods for the shearing lugs with different sections according to the relative design regulation and documents, undertakes the analysis and calculation, and compares their results, so as to reach the optimal design.
出处
《山西建筑》
2012年第18期55-56,共2页
Shanxi Architecture
关键词
塔架
钢柱脚
抗剪键
截面形式
正应力
剪应力
towers, steel column base, shear lug, section types, normal stress, shear stress