期刊文献+

IOL-Master测量硅油眼眼轴长的精确度评价 被引量:1

Accuracy of IOL-Master for Axial Length Measurements in Silicone Oil-filled Eyes
下载PDF
导出
摘要 目的评价IOL-Master测量硅油填充眼眼轴长的精确度。方法采用IOL-Master测定玻璃体切割联合眼内硅油填充术3~6个月后行硅油取出术的30例眼的眼轴长度。其中18例在硅油取出同时植入人工晶体(IOL),植入前后分别测量眼轴长。结果硅油取出术前后的眼轴平均长度分别为(24.27±3.01)mm和(24.26±2.79)mm,2组间差异无统计学意义。IOL-Master和A超2种方法测量硅油眼的眼轴长度无显著差异。结论 IOL-Master测量硅油眼眼轴长的精确度高,可用于硅油取出联合IOL植入的IOL度数计算。 Objective To evaluate the accuracy of axial length measured with IOL-Master in silicone oil-filled eyes. Methods This study was carried out on 30 eyes that received vitreous surgery with the vitreous replaced by silicone oil. Axial lengths were measured befiwe and after the removal of silicone oil. An IOL-Master was used for measurement. Eighteen eyes received implantation of intraocular lens (IOL) 'after removal. Results The axial length averaged (24.27 ±3.01 ) mm before and (24.26±2.79) mm after the removal of silicone oil. There was no significant difference between the two values. Refractions after IOL implantation measured by the present method and by the conventional ultrasound measurement were essentially the same. Conclusion There is no difference in axial lengths in eyes filled with or without silicone oil when measured by IOL-Master. IOL implantation can be performed immediately after the removal of silicone oil with the accurate axial length measured by IOL-Master.
出处 《中国医科大学学报》 CAS CSCD 北大核心 2012年第6期536-537,543,共3页 Journal of China Medical University
基金 国家自然科学基金资助项目(81000402)
关键词 IOL-MASTER 眼轴 硅油眼 IOL-Master axial length silicone oil filled eye
  • 相关文献

参考文献7

  • 1Sheng H, Bottjer CA, Bullimore MA. Ocular component measurement using the Zeiss IOL Master [J ]. Optorn Vis Sei, 2004,81 ( 1 ) :27-34.
  • 2Shugar JK,de Juan E Jr,McCuen BW,et al. Ultrasonic examination of the silicone-filled eye: theoretical and practical considerations [ J ]. Graefes Arch Clin Exp Ophthalmol, 1986,224(4) : 361-367.
  • 3Fledelius HC,Schherfig E. An ultrasonic response met in eyes after vitreoretinal surgery with silicone oil [J]. Acta Ophthalmol Scand, 2000,78( 1 ) :89-92.
  • 4Grinbaum A, Treiser G, Moisseiev J. Predicted actual refraction after intraocular lens implation in eyes with silicone oil [J]. J Cataract Refract Surg, 1996,22(6 ) : 726-729.
  • 5Murray DC,Potamitis T,Good P,et al. Biometry of the silicone oil- filled eye [J]. Eye, 1999, 13(pt 3a) :319-324.
  • 6Ghoraba HH,El-Dorghamy AA,Atia AF,et al. The problems of biometry in combined silicone oil removal and cataract extraction [ J ]. Retina, 2002,22(5 ) 589-596.
  • 7Sawa M,Saito Y,Hayashi A,et al. Assessment of nuclear sclerosis after nonvitrectomizing vitreous surgery [J]. Am J Ophthalmol, 2001,132(3 ) : 356-362.

同被引文献10

  • 1肖伟,陈明,盖春柳,杨宏伟,赵芳.不同仪器测量角膜曲率计算人工晶体屈光度的可行性分析[J].中国实用眼科杂志,2006,24(4):407-409. 被引量:13
  • 2Szurman P, Bartz-Schmidt KU. Silicone oils in retinal surgery [J]. Ophthalmologe, 2000,97 (7) : 514-525.
  • 3Chen W,McAlinden C,Pesudovs K, et al. Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: repeatability and agreement [J]. J Cataract Refract Surg,2012, 38(9) : 1626-1632.
  • 4Parravano M, Oddone F, Sampalmieri M, et al. Reliability of the IOLMaster in axial length evaluation in silicone oil-filled eyes[J]. Eye,2007,21(7):909-911.
  • 5Kunavisarut P, Poopattanakul P, Intarated C, et al. Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes[J]. Eye,2012,26(10):1344-1348.
  • 6Huaug J, McAlinden C, Su B, et al. The effect of cyeloplegia on the lenstar and the IOLMaster biometry[J]. Optom Vis Sci, 2012,89(12) : 1691-1696.
  • 7Bjelo$ Ron~evi~ M1,Bu~i~ M,Cima I, et al. Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence refleetometer [ J ]. Graefes Arch Clin Exp Ophthalmol, 2011,249 ( 1 ) : 83-87.
  • 8Hoffer K J, Shammas HJ, Savini G. Comparison of 2 laser instru- ments for measuring axial length[J]. J Cataract Refract Surg, 2010,36(4) : 644-648.
  • 9Federman JL, Schubert HD. Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery[J]. Ophthalmology, 1988,95 (7) : 870-876.
  • 10惠延年,王琳,黄蔚,韩泉洪,王英.增生性糖尿病视网膜病变患者玻璃体手术中植入人工晶状体的临床效果观察[J].中华眼科杂志,2002,38(10):598-602. 被引量:27

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部