本文主要介绍蒸发量为465t/h循环流化床(cFB)锅炉运行过程中给料系统频繁不下料事故的原因分析、发生堵塞后的应急处理以及循环流化床锅炉运行中针对给料系统频繁不下料的异常情况的防范措施。
The paper describes the cause of frequent no-feeding accident during the operation of the circulating fluidized bed (CFB) boiler feeding system with evaporation of 465t/h and also gives the corresponding preventive measures against it.