摘要
介绍了脱硫系统在线pH计的测量原理和吸收塔浆液的特性,分析了湿法烟气脱硫系统浆液pH值测量不准的原因,具体讲解了改造过程中遇到的难点和实施方案的要点。
The measuring principle and the characteristics of on - line pH meter in absorption tower of wet flue gas desulfurization system are analyzed. The factors of inaccurate measurement of pH value of slurry in absorption tower of wet flue gas desulfurization system are discussed. The difficulties during the transformation process and the key points of scheme implementation are concretely introduced.
出处
《电力科技与环保》
2012年第3期44-45,共2页
Electric Power Technology and Environmental Protection
关键词
脱硫
吸收塔
浆液pH
改造
FG D
absorption tower
grout pH
innovation