摘要 通过C18 ZipTip脱盐的方式,去除血清中的盐和脂类影响,直接进行质谱分析,采用700-3300Da的扫描范围,获得高质量的血清多肽图谱。实验结果表明,C18 ZipTip处理血清样品,是一种操作简便,重复性好,样品消耗少,有希望实现自动化的血清样品前处理方法。通过该方法对比正常小鼠和诱导产生卵巢癌小鼠的血清样品进行分析,发现了一系列在多肽在两组血清中存在差异,进一步研究将为卵巢癌的疾病诊断标志物发现提供了参考。
作者 洪剑锋
出处 《科技信息》 2012年第19期52-53,共2页 Science & Technology Information
  • 相关文献

参考文献9

  • 1Zhaojing Meng,Timothy D.Veenstr. Proteomic analysis of serum,plasma,and lymph for the identification of biomarkers[J].Proteomics Clin Appl,2007.747-757.
  • 2Harald Tarmmen,Imke Schulte. Peptidomic analysis of human blood specimens:Comparison between plasma specimens and serum by differential peptide display[J].Proteomics,2005.3414-3422.
  • 3Ahmed N,Barker G,Oliva K. An app roach to re move albumin for the proteomic analysis of low abundance biomarkers in human serum[J].Proteomics,2003,(10):1980-1987.doi:10.1002/pmic.200300465.
  • 4Cho,S,Lee,E. Efficient prefractionation of low abundance protein in human plasma and construction of a two dimensional map[J].Proteomics,2005.3386-3396.
  • 5Echan,L.A,Ali-Khan,N. Depletion of multiple high-abundance proteins improves protein profiling capacities of human serum and plasma[J].Proteomics,2005.3292-3303.
  • 6Yocum,A.K,Blair,I.A. Effect of imminoaffinity depletion of human serum during proteomics investigation[J].Journal of Proteome Research,2005.1722-1731.
  • 7Rothemund,D.L,Thomas,T.M. Depletion of the highly adundant protein albumin from human plasma using the Gradiflow[M].
  • 8Zolotarjova,N,Martosella,J. Differences among techniques for high-abundant protein depletion[J].Proteomics,2005.3304-3313.
  • 9陈东仕,金宏伟,黄慧英,翁鹭娜,黄河清.质谱技术在筛选肺癌血清差异多肽与蛋白质的应用[J].厦门大学学报(自然科学版),2006,45(B05):47-49. 被引量:1

二级参考文献6

  • 1Ahmed N, Barker G, Oliva K, et al. An approach to remove albumin for the proteomic analysis of low abundance biomarkers in human serum [J]. Proteomics, 2003, 3 :1980 - 1987.
  • 2Blackledge J A, Alexander A J. Polyethylene membrane as a sample support for direct matrix-assisted laser desorption/ionization mass spectrometric analysis of high mass proteins[J]. Anal. Chem.,1995, 67 : 843 - 848.
  • 3Huang H Q, Cao T M, Lin Q M. Characteristics of trapping copper ions with scrolled ferritin reactor in the flowing seawater[J]. Environ. Sci. Technol. , 2004, 38: 2476-2481.
  • 4Huang H Q, Xiao z Q, Lin Q M. Characteristics of structure, composition, mass spectra, and iron release from the ferritin of shark liver ( Sphyma zygaena) [J]. Biophys.Chem. , 2004, 111:213-222.
  • 5Benner W H, Hom D M, Jaklevic J M. Simultaneousmeasurement of flight time and energy of large matrix-assisted laser desorption ionization ions with a superconducting tunnel junction detector[J]. J. Am. Soc. Mass Spectrom. , 1997, 8: 1094-1102.
  • 6Flensburg J, Belew M. Characterization of recombinant human serum albumin using matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J]. J. Chromatorgra. A., 2003, 1009:111 -117.

同被引文献11

引证文献1

二级引证文献1