期刊文献+

质谱仪离子导向装置的原理、应用和进展 被引量:7

Principles,Applications and Progress of Mass Spectrometric Ion Guides
下载PDF
导出
摘要 离子导向装置(ion guide)是传输离子的重要手段。在质谱仪器中,离子导向装置是离子光学(ion op-tics)系统的重要组成部分,是联络处于低真空(或大气压)电离源和质量分析器的桥梁。离子导向装置不仅用于传输离子,还可降低离子的空间发散度和能量分散度,使离子最大限度到达质量分析器。本工作主要对一些常用的离子导向装置的原理、应用和进展进行了评述,并展望了未来的发展。 Ion guides are efficient ion transmission settings. In mass spectrometric apparatus, an ion guide is one of the major parts of ion optics, which connects the ionization source in low vacuum (or ambient atmosphere) and mass analyzer. Ion guides are used to transport ions with high efficiency, while reducing the spatial and energetic distribution. In this paper, we will review the principles, applications and progress of some conventional used ion guides, and anticipate its future development.
出处 《质谱学报》 EI CAS CSCD 北大核心 2012年第3期139-148,共10页 Journal of Chinese Mass Spectrometry Society
基金 国家自然科学基金同步辐射大气压光电离/质谱接口的设计研究及其应用(10979043)项目资助
关键词 质谱 离子导向装置 离子光学 mass spectrometry ion guides ion optics
  • 相关文献

参考文献41

  • 1WOLLNIK H. Ion optics in mass spectrometers [J]. Journal of Mass Spectrometry, 1999, 34 (10): 991-1 006.
  • 2HEDDLE D, KUREPA M. The focal properties of three-element electrostatic electron lenses [J]. Journal of Physics E.. Scientific Instruments, 1970, 3(7): 552.
  • 3HEDDLE D. The design of three-element electro- static electron lenses [J].Journal of Physics E: Scientific Instruments, 1969, 2(12): 1 046.
  • 4ADAMS A, READ F. Electrostatic cylinder len- ses Ih Three element einzel lenses [J]. Journal of Physics E: Scientific Instruments, 1972, 5 (2) : 150.
  • 5CHANG T, THOMSON M, KRATSCHMER E, et al. Electron - beam microeolumns for lithogra- phy and related applications [J]. Journal of Vacu- um Science & Technology B: Microelectronics and Nanometer Structures, 1996, 14 (6): 3 774- 3 781.
  • 6ROBBINS M D, YOON O K, ZULETA I, et al. Computer-controlled, variable-frequency power supply for driving multipole ion guides [J]. Re- view of Scientific Instruments, 2008, 79 (3) : 034702.
  • 7BOYD K J, LAPICKI A, AIZAWA M, et al. A phase-space-compressing, mass-selecting beamline for hyperthermal, focused ion beam deposition [J]. Review of Scientific Instruments, 1998, 69 (12): 4 106.
  • 8GUZOWSKI J R, HIEFTJE G M. Characteristics of a rf-only hexapole ion-guide interface for plas- ma-source time-of-flight mass spectrometry [J]. J Anal At Spectrom, 2001, 16 (8): 781-792.
  • 9ROTTGEN M A, JUDAI K, ANTONIETTI J M, et al. Conical oetopole ion guide: Design, focu- sing, and its application to the deposition of low energetic clusters [J].Review of Scientific Instru- ments, 2006, 77(1): 013302.