摘要 通过对25例维持性血液透析患者的静脉留置导管的护理进行总结,探讨维持性血液透析患者静脉留置导管的护理方法。护理重点包括严格无菌操作和及时准确地处理并发症,并做到使用、护理得当,则可以维持静脉留置导管通畅性,延长使用时间,保证透析顺利有效地进行。 This paper is a summary of 25 cases of maintenance hemodialysis patients with venous catheter care aiming to explore the methods. Nursing priorities include strict aseptic technique and timely and accurate handling complications properly, which can maintain intravenous catheter unobstructed, extend the time of use and ensure that dialysis is smooth and effective.
作者 詹文娴 李讯
出处 《襄樊职业技术学院学报》 2012年第3期51-52,共2页 Journal of Xiangfan Vocational and Technical College
关键词 维持性血液透析 静脉留置导管 护理 maintenance hemodialysis Venous Indwelling Catheter nursing
  • 相关文献

参考文献4

  • 1叶朝阳.中心静脉长期留置导管面临的挑战和对策[J].中国血液净化,2011,10(9):465-467. 被引量:44
  • 2Allon M.Fistu 1 a First : recent progress and ongoing challenges[J]. Am J Kidney Dis, 2011,5 (7) : 3-6.
  • 3Pastan S,Souee J M, Mcclellan WM.Vascular access and increased risk of death among hemodialysis patients [J]. Kidney lnt, 2002,62 (2) 620-626.
  • 4No authors Listed. United States Renal Data System[J]. Am J Kidney Dis, 1997,30(2) : 107-117.

二级参考文献19

  • 1Allon M.Fistula First:recent progress and ongoing challenges,Am J Kidney Dis,2011,57:3-6.
  • 2Polkinghorne KR,Seneviratne M,Kerr PG.Effect of a vascular access nurse coordinator to reduce central venous catheter use in incident hemodialysis patients:a quality improvement report.Am J Kidney Dis,2009,53:99-106.
  • 3Bradbury BD,Chen F,Furniss A,Pisoni RL,Keen M,Mapes D,et al.Conversion of vascular access type among incident hemodialysis patients:description and association with mortality.Am J Kidney Dis,2009,53:804-814.
  • 4Lacson E,Jr.,Wang W,Lazarus JM,Hakim RM.Change in vascular access and mortality in maintenance hemodialysis patients.Am J Kidney Dis,2009,54:912-921.
  • 5Lacson E,Jr.,Wang W,Hakim RM,Teng M,Lazarus JM.Associates of mortality and hospitalization in hemodialysis:potentially actionable laboratory variables and vascular access.Am J Kidney Dis,2009,53:79-90.
  • 6Goldstein SL,Ikizler TA,Zappitelli M,Silverstein DM,Ayus JC.Non-infected hemodialysis catheters are associated with increased inflammation compared to arteriovenous fistulas.Kidney Int,2009,76:1063-1069.
  • 7Wystrychowski G,Kitzler TM,Thijssen S,Usvyat L,Kotanko P,Levin NW.Impact of switch of vascular access type on key clinical and laboratory parameters in chronic haemodialysis patients.Nephrol Dial Transplant,2009,24:2194-2200.
  • 8Kanaa M,Wright M,Sandoe J.Examination of tunnelled haemodialysis catheters using scanning electron microscopy.Clin Micro and Infect,2010,16:780-786.
  • 9Qu Y,Istivan TS,Daley AJ,Rouch DA,Deighton MA.Comparison of various antimicrobial agents as catheter lock solutions:preference for ethanol in eradication of coagulase-negative staphylococcal biofilms.J Med Micro,2009,58:442.
  • 10Landry DL,Braden GL,Gobeille SL,Haessler SD,Vaidya CK,Sweet SJ.Emergence of gentamicin-resistant bacteremia in hemodialysis patients receiving gentamicin lock catheter prophylaxis.Clin Am Soc Nephrol,2010,5:1799.