摘要 针对微型功率双幅有源箝位谐振直流环节逆变器在正常工作过程中,传统箝位电压平衡母线短路控制策略带来损耗大的问题,开展了直流环节工作过程的分析,针对直流环节正常工作的情况下,箝位电容电压必须能平衡在设定值,提出了箝位电压平衡母线无短路控制策略,根据给出的损耗估算方法,通过Mathcad计算,对比了母线短路控制和无短路控制两种方式下的损耗,同时计算出了母线无短路控制箝位电容电压纹波不大于20%下的箝位电容参数。研究结果表明:微型功率ACRDCLI箝位电压平衡采用母线无短线控制,不但可以减少双幅有源箝位谐振直流环节逆变器的损耗,并且可以使用薄膜电容作为箝位电容,以达到微型功率ACRDCLI损耗低、寿命长的要求。 Aiming at the big loss of the traditional clamping voltage balance control strategies, in two-amplitude actively clamped resonant DC-LINK inverter,the work process of DC link was analyzed. In order to keep the clamp capacitor voltage balance the value set in DC-link work, no short-circuit control was proposed.The DC-link of inverter was calculated by Mathcad. The loss of two modes of short-eireuit control and no short-circuit control were compared.Under the no short-circuit control and voltage ripple is not be greater than twenty percent, the parameters of the clamp capacitor were calculated. The results indicate that, the micro-power ACRDCLI clamping voltage balance use no short-circuit control,that can reduce the loss of the DC link and can use thin-film capacitor as a clamp capacitor to achieve the micro-power ACRDCLI low loss and long life requirements.
出处 《机电工程》 CAS 2012年第6期696-699,704,共5页 Journal of Mechanical & Electrical Engineering
基金 国家自然科学基金青年科学基金资助项目(51107117)
关键词 双幅控制 谐振直流环 损耗计算 箝位电压平衡 two amplitude control resonant DC-link loss calculation clamping voltage balance
  • 相关文献

参考文献8

二级参考文献11

  • 1李志国.双幅有源钳位谐振直流环逆变器的研究(硕士论文)[M].浙江大学,2000..
  • 2[1]Divan D M. The resonant DC link converter-a new concept in static power conversion. in Proc, IEEE- IAS Ann. Mtg. 1986, 648~656
  • 3[2]Divan D M, Skibinski G.Zero-switching-loss inverters for high power applications. in Conf, Rec, IEEE-IAS Annu. Meeting, 1987, 627~634
  • 4[3]Ying Jianping, Heumann Klemens. Two-amplitude active clamped resonant DC link inverter. IPEMC'97, Hangzhou,China. 554 ~ 562
  • 5[1]Ying Jianping,Heumann K.Two- amplitude active clamped resonant dc link inverter[C].in IPEMC'97,554-562.
  • 6[2]Ying J P,Li G Z,Zhang D H,et al.A novel two amplitudes scheme for he actively clamped resonant dc link inverter[C].Proc. IEEE PEDS Ann. Meeting.1999,1096-1101.
  • 7[3]Divan D M,Venkataramanan G,DeDoncker R W A A.Design methodologies for soft switched inverters[J].IEEE Transactions on Industry Applications,1993,29(1):126-135.
  • 8[4]Divan D M.The resonant DC link converter-a new concept in static power conversion[J].IEEE Transactions on Industry Applications, 1989,25(22):317-325.
  • 9[5]Divan D M,Skibinski G.Zero-switching-loss inverters for high-power applications[J].IEEE Transactions on Industry Applications,1989,25(4):634-643.
  • 10李志国,硕士论文,2000年

共引文献19

同被引文献21

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部