期刊文献+

击穿抗电装置的容量指标

On the Capacity Performance Index of Voltage resisting and Puncture Testers
下载PDF
导出
摘要 目的 根据影响介质击穿的主要因素 ,阐述了交流击穿抗电装置的容量指标问题 .方法 在确定击穿抗电装置的容量时 ,不仅要考虑到被试样件两极间的等效电容值 ,同时还要估计到样件在击穿过程可能产生的最大击穿电流值 .结果与结论 对于某种绝缘材料或者构件 。 Aim\ On the basis of primary factors influencing puncture of mediums, this paper emphatically points out the capacity performance index of voltage resisting and puncture tester. Methods\ When its capacity is defined, it would consider the equivalent capacitance of test sample between electrodes, and would estimate the highest puncture current value of test sample producing in the puncturing course. Results and Conclusion It is very important to choose rationally the capacity of voltage resisting and puncture test for some insulating material and componeuts.
作者 于治会
出处 《华北工学院测试技术学报》 2000年第1期66-70,共5页 Journal of Test and Measurement Technology
关键词 绝缘材料 介质电穿 抗电试验 容量指标 insulating materials dielectric breakdown electrical test capacity
  • 相关文献

参考文献4

  • 1GB1408-75.固体电工绝缘材料工频击穿电压、击穿强度和耐压试验.
  • 2[5]GB1695-81, 硫化橡胶工频击穿介质强度和耐压的测定方法[S].
  • 3[6]GB1408-78, 击穿电压、击穿强度和耐压试验[S].
  • 4GB998-67.低压电器.基本试验方法.

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部