光学表面等离子共振测定盐酸克伦特罗的试验研究 被引量:10

Experimental study on detection of clenbuterol hydrochloride using surface plasmon resonance
下载PDF
导出
摘要 为了实现高灵敏度定量检测盐酸克伦特罗,提出了一种新颖的、无标记、快速的内嵌TSPR1K23生物传感器的光学表面等离子共振(Surface plasmon resonance,SPR)盐酸克伦特罗测定方法,并通过试验验证了光学表面等离子共振生物测定装置的性能.光学表面等离子共振盐酸克伦特罗测定装置由集成光学SPR生物传感器、微流通池、便捷更换芯片的夹具、触电屏,USB接口板及光电转换电路板组成.在光学SPR芯片金膜表面固定盐酸克伦特罗抗原,在标准样品中(盐酸克伦特罗抗体质量浓度33.75 mg·L-1)分别添加0,10,20,40 mg·L-1的盐酸克伦特罗抗原,采用竞争免疫反应方法建立的盐酸克伦特罗测定标准曲线,相关系数0.997,相对标准偏差6.5%. In order to realize a high sensitive quantitative detection of residual clenbuterol hydrochloride(CLB),an novel and label-free surface plasmon resonance(SPR) analytical approach based on the TSPR1K23 biosensor was systematically proposed,and validated experimentally for its high performance.This device is composed of an integrated biosensor,a micro-flow cell,a clamp,a touch monitor screen and an electrical control unit(ECU) incorporated with a photoelectric conversion board and a USB interface board.In this study,the measurement approach was validated using the clenbuterol hydrochloride surface antigen as an example.The antigen-CLB is immobilized to the surface of the biosensor chip by a self-assembly technology.The antigen-CLB samples at 0,10,20,40 mg·L-1 were respectively added into the standard solution of antibody-CLB(mass concentration 33.75 g·mL-1),and a fitting curve is obtained,which optimized with a R-squared value 0.997,RSD 6.5%.
出处 《河南农业大学学报》 CAS CSCD 北大核心 2012年第2期198-202,共5页 Journal of Henan Agricultural University
基金 国家863计划项目(2007AA100606) 河南省杰出青年基金项目(104100510017) 河南省教育厅创新人才项目(2009HASTIT019) 郑州市科技领军人才项目(096SYJH25101)
关键词 光学表面等离子(SPR) 盐酸克伦特罗 生物传感器 微流池 surface plason resonance; clenbuterol hydrochloride; biosensors; micro-flow cell;
  • 相关文献

参考文献15

  • 1张絜青,陈煦,刘清.固相萃取-超高效液相色谱串联质谱测定猪肉中瘦肉精方法研究[J].中国卫生检验杂志,2010,20(9):2182-2183. 被引量:4
  • 2王硕,李细芬,生威,张燕,杨泽琳,方国臻.增强化学发光酶免疫法对猪肉中盐酸克伦特罗的检测[J].分析测试学报,2010,29(3):215-219. 被引量:21
  • 3GB/T22286-2008.动物源性食品中多种8-受体激动剂残留的测定液相色谱-质谱/质谱法[S].北京:中国标准出版社,2008.
  • 4孙霞,王相友,王小瑜.用于农药残留快速检测的生物传感器灵敏度筛选试验[J].农业工程学报,2009,25(3):295-297. 被引量:12
  • 5赵媛媛,蒋国良,高献坤,胡建东,胡敬芳,张润娜,汪兴莉.改进的光学表面等离子共振角度光谱分析方法[J].河南农业大学学报,2009,43(5):535-539. 被引量:4
  • 6SCHUCK P, MINTON A P. Mininal requirements forinternal consistency of the analysis of surface plasmonresonance biosensor data [ J ]. Trends Biochem Sci,1996, 21(4):58-60.
  • 7ALEXI N N,SCOLL D S, DWIGHT U B, et al. A portable surface plasmon resonance (SPR) sensor systerm with temperature regulation[ J]. Sensors and Actuators B, 2003, 96(I/2) :253 -260.
  • 8HU J D, HU J F, LUO F H, et al. Design and validation of a low cost surface plasmon resonance bioanalyzer using microprocessors and a touch-screen monitor [ J ]. Biosensors and Bioelectronics, 2009,24 (7) : 1974 - 1978.
  • 9HO H P, WU S Y, YANG M, et al. Application ofwhite light-emitting diode to surface plasmon resonancesensor[ J ]. Sensors and Actuators B : Chemical, 2001,80(2) :89 -94.
  • 10WU L, ZHANG Q, SU L. Effects of small molecular inhibitors on the binding between HIV-1 reverse transcriptase and DNA as revealed by SPR biosensor [ J ]. Sensors and Actuators B: Chemical, 2007, 122 ( 1 ) : 243 - 252.

二级参考文献84

共引文献65

同被引文献238

引证文献10

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部