期刊文献+

用石英晶体微天平研究酪蛋白在不同固液界面上的固定化及酶解行为 被引量:2

Casin Immobilization and Enzymolysis Behaviors at Different Solid-Aqueous Interfaces by Quartz Crystal Microbalance
原文传递
导出
摘要 使用石英晶体微天平(QCM)研究了酪蛋白在聚苯乙烯、Au和SiO2三种芯片表面上的吸附与酶解行为.结果表明,酪蛋白在聚苯乙烯表面具有较高的非特异性吸附,吸附量为127.9ng/cm2,而在空白Au和SiO2表面几乎没有非特异性吸附.通过对Au和SiO2表面进行修饰和活化,酪蛋白可共价固定化在其表面,固定化量分别为178.0和1718.0ng/cm2.用胰蛋白酶对吸附的酪蛋白水解后,再用表面活性剂洗涤,可以完全去除聚苯乙烯表面的酪蛋白和其酶解产物,而单独使用表面活性剂仅能洗涤约36%吸附的酪蛋白.建立了用QCM测定胰蛋白酶在固液界面酶解酪蛋白酶活的方法,对共价固定化在修饰后Au和SiO2表面上的酪蛋白,胰蛋白酶的水解活性分别为0.010和0.157U/mg,远低于水解游离酪蛋白的17.8U/mg. A quartz crystal microbalance (QCM) with dissipation monitoring was used to characterize the adsorption and subsequent trypsin-catalyzed hydrolysis of casin molecules at several typical interfaces, including Au, SiO2 and polystyrene coated chip surfaces. The results showed that a high non-specific adsorption amount of 127.9 ng/cm2 was observed for casin on polystyrene chip surface, while no apparent adsorption occurred on native Au and SiO2 chips. After activation and modification, casin was covalently immobilized on Au and SiO2 chip surfaces with the amounts of 178 and 1 718 ng/cm2, respectively. The subsequent enzymolysis of attached casin by injection of typsin was also monitored using QCM. After trypsin treatment, casin molecules and its hydrolysate peptide adsorbed on polystyrene surface could be efficiently removed with surfactant, without trypsin pre-treatment, however, only 36% of the adsorbed casin was removed by surfactant. A method for measuring activity of trypsin at solid-aqueous interfaces was developed. The measured specific hydrolytic activities of trypsin for immobilized casin on Au and SiO2 chip surfaces are 0.010 and 0.157 U/mg, respectively, which was lower than that for free casin in solution with the specific activity of 17.8 U/mg.
出处 《过程工程学报》 CAS CSCD 北大核心 2012年第3期440-446,共7页 The Chinese Journal of Process Engineering
基金 国家重点基础研究发展规划(973)基金资助项目(编号:2009CB724705) 国家自然科学基金资助项目(20728607 20976180 20820102036 21106160)
关键词 石英晶体微天平 界面吸附 酶解 酪蛋白 胰蛋白酶 quartz crystal microbalance interfacial adsorption enzymolysis casin trypsin
  • 相关文献

参考文献19

  • 1Maurer K H. Detergent Proteases [J]. Curr. Opin. Biotechnol., 2004, 15(4): 330-334.
  • 2Bates I R, Matharu P, Ishiyama N, et al. Characterization of a Recombinant Murine 18.5 kDa Myelin Basic Protein [J]. Protein Expression and Purification, 2000, 20(2): 285-299.
  • 3Aoyagi S, Okada K, Shigyo A, et al. Evaluation of Oriented Lysozyme Immobilized with Monoclonal Antibody [J]. Appl. Surf. Sci., 2008, 255(4): 1096-1099.
  • 4Hanefeld U, Gardossi L, Magner E. Understanding Enzyme Immobilisation [J]. Chem. Soc. Rev., 2009, 38(2): 453-468.
  • 5Carter R, Mekalanos J, Jacobs M, et al. Quartz Crystal Microbalance Detection of Vibrio Cholerae O139 Serotype [J]. J. Immunol. Methods, 1995, 187(1): 121-125.
  • 6Su Z H, Chen L, Liu Y, et al. 35 MHz Quartz Crystal Microbalance and Surface Plasmon Resonance Studies on the Binding of Angiotensin Converting Enzyme with Lisinopril [J]. Biosens. Bioelectron., 2010, 26(7): 3240-3245.
  • 7Santos J P, Welsh E R, Gaber B P, et al. Polyelectrolyte-assisted Immobilization of Active Enzymes on Glass Beads [J]. Langmuir, 2001, 17(17): 5361-5367.
  • 8Fogel R, Limson J. Probing Fundamental Film Parameters of Immobilized Enzymes towards Enhanced Biosensor Performance: Part I. QCM-D Mass and Rheological Measurements [J]. Enzyme Microb. Technol., 2011, 49(2): 146-152.
  • 9Nihira T, Mori T, Asakura M, et al. Kinetic Studies of Dextransucrase Enzyme Reactions on a Substrate or Enzyme-immobilized 27 MHz Quartz Crystal Microbalance [J]. Langmuir, 2011, 27(6): 2107-2111.
  • 10Turon X, Rojas O J, Deinhammer R S. Enzymatic Kinetics of Cellulose Hydrolysis: A QCM-D Study [J]. Langmuir, 2008, 24(8): 3880-3887.

同被引文献92

  • 1谭碧生,莫志宏.石英晶体微天平电极表面的原位物理化学研究[J].中国矿业,2005,14(2):80-83. 被引量:2
  • 2王久才,蒋海峰,张培仁.基于频谱分析的QCM信号采集系统[J].仪表技术与传感器,2006(2):23-24. 被引量:3
  • 3Sauerbrey G.Zeitschrift Für Physik[J],1959,155(2):206.
  • 4Kanazawa K K,Gordon J G.Analytical Chemistry[J],1985,57(8):1770.
  • 5Cooper M A,Singleton V T.Journal of Molecular Recognition[J],2007,20(3):154.
  • 6Rodahl M,Hk F,Krozer A,Brzezinski P,Kasemo B.Review of Scientific Instruments[J],1995,66(7):3924.
  • 7Wang D Z,Tang W,Wu X J,Wang X Y,Chen G J,Chen Q,Li N,Liu F.Analytical Chemistry[J],2012,84(16):7008.
  • 8Tang W,Wang D Z,Xu Y,Li N,Liu F.Chemical Communications[J],2012,48(53):6678.
  • 9Wang D Z,Chen G J,Wang H M,Tang W,Pan W,Li N,Liu F.Biosensors and Bioelectronics[J],2013,48:276.
  • 10Fei Y H,Jin X Y,Wu Z S,Zhang S B,Shen G L,Yu R Q.Analytica Chimica Acta[J],2011,691(1-2):95.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部