期刊文献+

Coagulation efficiency and flocs characteristics of recycling sludge during treatment of low temperature and micro-polluted water 被引量:12

Coagulation efficiency and flocs characteristics of recycling sludge during treatment of low temperature and micro-polluted water
原文传递
导出
摘要 Drinking water treatment sludge,characterized as accumulated suspended solids and organic and inorganic matter,is produced in large quantities during the coagulation process.The proper disposal,regeneration or reuse of sludge is,therefore,a significant environmental issue.Reused sludge at low temperatures is an alternative method to enhance traditional coagulation efficiency.In the present study,the recycling mass of mixed sludge and properties of raw water (such as pH and turbidity) were systematically investigated to optimize coagulation efficiency.We determined that the appropriate dosage of mixed sludge was 60 mL/L,effective initial turbidity ranges were below 45.0 NTU,and optimal pH for DOMs and turbidity removal was 6.5-7.0 and 8.0,respectively.Furthermore,by comparing the flocs characteristics with and without recycling sludge,we found that floc structures with sludge were more irregular with average size growth to 64.7 μm from 48.1 μm.Recycling sludge was a feasible and successful method for enhancing pollutants removal,and the more irregular flocs structure after recycling might be caused by breakage of reused flocs and incorporation of powdered activated carbon into larger flocs structure.Applied during the coagulation process,recycling sludge could be significant for the treatment of low temperature and micro-polluted source water. Drinking water treatment sludge,characterized as accumulated suspended solids and organic and inorganic matter,is produced in large quantities during the coagulation process.The proper disposal,regeneration or reuse of sludge is,therefore,a significant environmental issue.Reused sludge at low temperatures is an alternative method to enhance traditional coagulation efficiency.In the present study,the recycling mass of mixed sludge and properties of raw water (such as pH and turbidity) were systematically investigated to optimize coagulation efficiency.We determined that the appropriate dosage of mixed sludge was 60 mL/L,effective initial turbidity ranges were below 45.0 NTU,and optimal pH for DOMs and turbidity removal was 6.5-7.0 and 8.0,respectively.Furthermore,by comparing the flocs characteristics with and without recycling sludge,we found that floc structures with sludge were more irregular with average size growth to 64.7 μm from 48.1 μm.Recycling sludge was a feasible and successful method for enhancing pollutants removal,and the more irregular flocs structure after recycling might be caused by breakage of reused flocs and incorporation of powdered activated carbon into larger flocs structure.Applied during the coagulation process,recycling sludge could be significant for the treatment of low temperature and micro-polluted source water.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第6期1014-1020,共7页 环境科学学报(英文版)
基金 supported by the Important Project of Science and Technology for Water Pollution Control and Treatment (No:2009ZX07424-005-01)
关键词 recycling sludge sweep flocculation adsorption flocs characteristics recycling sludge sweep flocculation adsorption flocs characteristics
  • 相关文献

参考文献1

二级参考文献4

共引文献3

同被引文献55

  • 1刘继平.污泥回流法处理低温低浊水的试验研究[J].给水排水,1995,21(1):12-15. 被引量:21
  • 2王东升,刘海龙,晏明全,余剑锋,汤鸿霄.强化混凝与优化混凝:必要性、研究进展和发展方向[J].环境科学学报,2006,26(4):544-551. 被引量:75
  • 3XIA Sheng-ji,LIU Ya-nane,LI Xing,YAO Juan-juan.Drinking water production by uitrafiltration of Songhuajiang River with PAC adsorption[J].Journal of Environmental Sciences,2007,19(5):536-539. 被引量:31
  • 4付英,于水利,杨园晶,芦艳.聚硅酸铁(PSF)混凝剂硅铁反应过程研究[J].环境科学,2007,28(3):569-577. 被引量:21
  • 5Guan X H, Chen G H, Shang C. Re-use of water treatment works sludge to enhance particulate pollutant removal from sewage [J] .Water research,2005,39 ( 15):3433 -3440.
  • 6Cheng W P. Comparison of hydrolysis/coagulation behavior of poly- meric and monomeric iron coagulants in humic acid solution[J]. Chemosphere,2002,47(9):963 -969.
  • 7Gao B Y, Chu Y B, Yue Q Y, et al. Characterization and coagulation of a polyaluminum chloride (PAC) coagulant with high A1 13 content [J].Joumal of Environmental Management,2005,76(2): 143-147.
  • 8Yu W, Gregory J, Campos L C. Breakage and re-growth of floes formed by charge neutralization using alum and poly DADMAC[J]. Water research,2010,44(13):3959-3965.
  • 9McCurdy K, Carlson K, Gregory D. Floc morphology and cyclic shearing recovery: comparison of alum and polyaluminum chloride coagulants[J].Water Research,2004,38(2):486-494.
  • 10MeCurdy K, Carlson K, Gregory D. Floe morphology and cyclic shearing recovery: comparison of alum and polyalum!num chloride coagulants[J].Water Research,2004,38(2):486-494.

引证文献12

二级引证文献88

相关作者