本文针对1000MW超超临界燃煤机组,采用了180度双入口脱硫吸收塔,分别模拟和比较了单双侧进烟时,隔板对流场的分布状况,提出了最佳的布置方式。
In this paper, aiming at 1000 MW nltra-supercritical coal-fired units, adopting FGD system with 180-degree double inlet, the effect of baffle on flow field distribution with one-side and two-side for exhaust gas feeding were simulated and compared. The optimal lay out was proposed.