期刊文献+

基于健康人群唾液葡萄糖检测体系的构建 被引量:3

Establishment of saliva glucose detection system for healthy subjects
下载PDF
导出
摘要 目的为实现对健康人群进行日常的无创血糖监测,构建基于唾液的高灵敏度葡萄糖检测体系。方法通过对反应体系最适pH值、离子强度的筛选及酶活性调节剂柠檬醛的添加,对以2,4,6-三溴-3-羟基苯甲酸(TBHBA)为色原的葡萄糖氧化酶法进行改良。结果新构建的葡萄糖检测体系反应30 min趋于完全,在510 nm最大吸收波长下检测吸光度(A)值,得到优化参数组合为pH值5.8、0.3 mol/L NaCl、1 220μg/mL柠檬醛。葡萄糖检测低限0.006 mmol/L。结论优化后的检测体系灵敏度是原体系约7倍,检测低限为健康人空腹时唾液葡萄糖平均浓度的1/10,完全达到检测健康人唾液葡萄糖浓度的灵敏度要求。 Objective To establish a high sensitive detection system to detect the glucose level in saliva in order to realize the daily noninvasively blood glucose monitoring for healthy subjects. Methods The method of glucose oxidase-peroxidase with 2,4,6-tribromo-3-hydroxybenzoic acid (TBHBA) as chromogen was modified, in which pH value and the consistency of ion were optimized, and citral was added to adjust the activity of the enzyme. Results The reaction of the new detection system could be completed in 30 min, and the maximal absorbing wavelength of detecting absorbance (A) value was 510 nm. The optimization of the new detection system parameters was pH: 5.8, 0.3 mol/L NaC1 and 1 220 μg,/mL citral. The low limit value of glucose level detection was 0. 006 mmol/L. Conclusions The sensitivity of the optimized detection system is about 7 times more than that of the original system. The low limit value is 1/10 of fasting saliva glucose mean level in healthy subjects. It is sensitive enough to detect the glucose level in saliva of healthy subjects.
出处 《检验医学》 CAS 2012年第6期486-490,共5页 Laboratory Medicine
基金 中日合作研究项目 Non-invasive Blood Glucose Monitoring with Saliva(No.R-21-5)
关键词 葡萄糖 唾液 健康人群 检测 Glucose Saliva Healthy subject Detection
  • 相关文献

参考文献10

  • 1Yamaguchi M, Mitsumori M, Kano Y. Noninvasively measuring blood glucose using saliva[ J]. IEEE Eng Med Biol Mag, 1998, 17 (3) : 59-63.
  • 2Sashikumar R, Kannan R. Salivary glucose levels and oral candidal carriage in type II diabetics [ J ]. OralSurg Oral Med Oral Pathol Oral Radiol Endod, 2010, 109 (5) : 706-711.
  • 3付雪艳,于福生,董琳,张义伟,马学琴.正常大鼠及糖尿病大鼠血糖昼夜节律性研究[J].时珍国医国药,2007,18(9):2216-2217. 被引量:1
  • 4崔云龙,姚桂玲,李玲,嵇志珍,王茂.用2.4.6-三溴-3-羟基苯甲酸色原测定血糖[J].临床检验杂志,1992,10(1):24-25. 被引量:4
  • 5梅建生,张雅利,禹帅.唾液葡萄糖与血液葡萄糖的检测与相关性分析[J].激光生物学报,2006,15(1):94-96. 被引量:6
  • 6赵勤实,从玉文.迈克尔反应受体分子化学生物学研究[J].化学进展,2007,19(12):1972-1976. 被引量:13
  • 7Kumar A, Malik F, Bhushan S, et al. An essential oil and its major constituent isointermedeol induce apoptosis by increased expression of mitochondrial cytochrome c and apical death receptors in human leukaemia HL-60 cells [ J ]. Chem Biol Interact, 2008, 171 (3): 332-347.
  • 8Dudai N, Wenstein Y, Krup M, et al. Citral is a new inducer of caspase-3 in tumor cell lines [ J ]. Planta Med, 2005, 71 (5) : 484-488.
  • 9Veitch NC. Horseradish peroxidase: a modern view of a classic enzyme [J]. Phytochemistry, 2004, 65 (3) : 249-259.
  • 10Shen J, Goyal A, Sperling L. The emerging epidemic of obesity, diabetes, and the metabolic syndrome in China[J]. Cardiol Res Pract. 2012: 178675.

二级参考文献40

  • 1姜小鹰.SPSS软件简明教程[M].福州:福建教育出版社,2004:8.
  • 2MASAKI Y,MASAYUKI M、 YOSHIO K.Noninvasive Measuring Blood Glucose Using Saliva[J].Engineering in Medicine and Biology,1998,17 (3):59-63.
  • 3何绍雄.时间药理学和时间治疗学[M].天津:天津科学技术出版社,1998:1.
  • 4Michael A. J. Prakt. Chem., 1887, 35:349-356
  • 5Powers J C, Asgian J L, Ekici O D, et al. Chem. Rev., 2002, 102 : 4639-4750
  • 6Barrett A J, Kembhavi A A, Brown M A, et al. Biochem. J., 1982, 201:189-198
  • 7Ekici O D, Li Z Z, Powers J C, et al. J. Med. Chem., 2006, 49 : 5728-5748
  • 8Clapharm D E. Nature, 2003, 426:517-524
  • 9Jordt S E, Bautista D M, Julius D, et al. Nature, 2004, 427: 260-265
  • 10Trevisani M, Siemens J, Julius D, et al. Proc. Natl. Aead. Sci. USA, 2007, 104:13519-13524

共引文献20

同被引文献37

  • 1鲍淑娣,张元亭.远程医疗:穿戴式生物医疗仪器[J].中国医疗器械信息,2004(5):1-3. 被引量:42
  • 2黄辉,乔羽,魏明竟,李招权,蒲晓允.唾液葡萄糖比色测定方法的建立及应用[J].现代口腔医学杂志,2005,19(6):621-623. 被引量:8
  • 3钱莺.血糖监测方法的研究进展[J].护理研究(上旬版),2006,20(8):1988-1989. 被引量:13
  • 4PoonC C Y, WongN Y M, ZhangYT. M-Health: the development of cuff - less and wearable blood pressure me- ters for use in body sensor networks [J]. Life Science Sys- tems and Applications Workshop, 2006, (7) : 1 - 2.
  • 5Mortellaro M, DeHennis A. Performance Characterization of an Abiotic and Fluorescent -based Continuous Glucose Mo- nitoring System in Patients with Type 1 Diabetes [ J ]. Bio- sensors and Bioelectronics, 2014, (61) : 227 -251.
  • 6Koschinsky T, Heinemann L. Sensors for Glucose Monito- ring: Technical and Clinical Aspects [ J]. Diabetes/Metab- olism Research & Reviews, 2001, 17 (2) : 113 - 123.
  • 7McNichols R J, Cote G L. Optical Glucose Sensing in Bio- logical Fluids: an overview [ J]. Journal of Biomedical Op- tics, 2000, 5 (1): 5-16.
  • 8Oliver N S, Toumazou C, Cass A E G, et al. Glucose Sen- sors : a review of current and emerging technology [ J]. Dia- betic Medicine, 2009, 26 (3) : 197 -210.
  • 9Chuah Z M, Paramesran R, Thambiratnam K, et al. A Two -level Partial Least Squares System for Non - invasive Blood Glucose Concentration Prediction [ J ]. Chemometrics and InteUigent Laboratory Systems, 2010, 104 (2): 347 - 351.
  • 10Barman I, Kong C R, Singh G P, et al. Accurate Spectro- scopic Calibration for Noninvasivc Glucose Monitoring by Modeling the Physiological Glucose Dynamics [ J]. Analyti- cal Chemistry, 2010, 82 (14) : 6104 -6114.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...