摘要 目前,大型江水源热泵空调系统在长江中下游地区得到越来越多的应用。本文以南京国际服务外包产业园江水源热泵区域供冷供暖项目为例,分析了江水源热泵造成水体水质和热污染的可能性及其预防措施。分析认为,通过采取适当措施和总量适度控制,江水源热泵系统的推广应用,对环境不会造成实质性的影响,并且通过科学的规划设计,对江水退水的综合利用还能够对城市环境带来一定的改善。 At present, the Yangtze River water source heat pump air conditioning system is a large domestic, especially the middle reaches area of Yangtze River is getting more and more applications. This article take the Nanjing International Service Outsourcing Industrial Park area of Yangtze River water source heat pump cooling and heating project as an example, analyzes the causes of water quality of Yangtze River water source heat pump and water heat pollution and the possibility of its prevention measures. The analysis thinks, through appropriate measures and gross measurable control, Yangtze River water source heat pump system application, on the environment does not cause substantial effects, and through scientific planning of the Yangtze River water, return water comprehensive utilization is also able to bring certain of improving city environment.